Appendix: Technical data
These specifications for the electrical connection and the standards quoted
apply for connecting the coffee machine in EU countries. It may be necessary to
also observe additional country-specific regulations. Outside the EU countries
acceptance of the standards quoted is to be checked by the legal entity or natural
person who wishes to use the coffee machine.
The local power supply must be constructed according to IEC 364 (DIN VDE 0100).
Toimprove safety, the device should be fitted with an FI 30mA earth leakage current
circuit breaker complying with EN 61008. (Type Bresidual current circuit breakers
provide reliable tripping even if the fault current is smooth. This ensures ahigh level
of safety.) Near the device or about 30cm below the counter top there should be
ashockproof socket as asingle-phase connection installed locally on the rear or side
wall of the counter substructure or acountry-specific single-phase socket and, in the
case of a3-phase connection, a5-pin CEE/CEKON-socket according to EN 60309or
acountry-specific multi-pin socket. The mains switch and plug top are part of the
on-site installation. The mains cable must not come into contact with hot surfaces. If the
mains cable for this device is damaged then it must be replaced by our service personnel
or asimilarly qualified person, in order to prevent hazards. The coffee machine may not
be fitted with afixed permanent mains connection if installed on atransporting trolley
(a mobile station).
In order to avoid possible faults from arising on our shielded data lines due to potential
equalisation currents between the devices, an additional potential equalisation unit
should be planned for devices connected to the vending system. (See EN 60309)