User's Manual

Repeater Operation
3-1
CHAPTER 3
OPERATION
3-1 INTRODUCTION
This chapter provides information for operating the PCS Repeater. The R1910 is designed to work
in an indoor environment only, while the R1920/30/40 is designed to work in an outdoor
environment.
The R1910 and R1920/30/40 are fully compliant with FCC part 24. For the R1910, there are no
panel controls other than the power switch. For the R1920/30/40, there are no external controls or
indicators. Access to A/C power connects and interface connections are via an access panel.
The operator must be familiar with the control software being used and the operation and functional
capabilities of the R19X0.
3-2 OPERATING INSTRUCTIONS
The following paragraphs provide a description of the control functions and operation of the
R19X0 PCS Repeater.
3-2.1 Power-up Sequence
For the R1910, to turn on the unit, push the “1” side of the power switch rocker arm to the depressed
position. For the R1920/30/40, remove the access panel and push the power switch. The unit will
go through an initialization, which includes restoring the unit to its last powered-up state and
checking the alarm status.
Table 3-1. Initial Parameter Status
Parameter R1910 Initial Value R1920/30/40 Initial Value
Band AD,BE,FC AD,BE,FC
Channel 0-1199 CDMA
1-1999 TDMA
512-810 PCS-1900
(GSM)
0-1199 CDMA
1-1999 TDMA
512-810 PCS-1900 (GSM)
DOWNLINK RF 1930-1990MHz 1930-1990MHz
DOWNLINK Gain 65-95dB 65-95dB
DOWNLINK Power Out 0 to +27dBm +15 to +41.5dBm
UPLINK RF 1850-1910MHz 1850-1910MHz
UPLINK Gain 65-95dB 65-95dB
UPLINK Power Out 0 to +27dBm 0 to +27dBm
UPLINK RSS > -70dBm >-70dBm
Alarms Green Green