Data Sheet

How to use USPACE-KYD-2F
3 How to use
3.1 Just charge-and-play
The tag is fully pre-configured and not requiring any initial setup through web or mobile
application.
The tag is fully autonomous, its alerting functionality does not depend on the availability of any
local or global network connection. In particular, even in real-time monitoring mode, the absence of
DASH7 connectivity does not alter the alerting functionality. Reports history, when enabled,
remains accessible in the tag’s flash memory.
3.2 First enable
When produced and conditioned for shipping, the devices are set in deepsleep mode (aka shelf
mode). They are completely inactive, do not scan nor measure distances, the BLE and NFC
interfaces are disabled (no any intentional radio emissions).
In order to set the device to monitoring mode (aka tag mode), one should connect it to an electronic
device’s USB port or 5V DC power supply with USB connector using the provided USB adaptation
cable. This will start charging the battery and set the device to charging mode (and exit shelf mode).
WIZZILAB Technical datasheet 8/20