Data Sheet
Table Of Contents
Advanced Configuration USPACE-KYD-2F
the presence of Gateways, it is better to keep the TAG plugged all the time while remaining
active.
• Passive: When checked this option prevents the TAG to actively discover the neighboring
TAGs. It will still answer other TAGs discovery requests
• AutoSleep: When no motion is detected for “Stable Assert Delay” seconds, the TAG will
go to sleep mode
• Reporting Mode
◦ IMMEDIATE: Real time uplink
◦ OPPORTUNISTIC: Upload in presence of an "Upload" TAG
◦ LOG_ONLY: Logs saved in EEPROM, no reporting (readback not implemented)
◦ NONE: No logs saved – Use for standalone mode
ALARM MASK: Masks applied in case of alarm
• No Buzzer: Disable Buzzer
• No Vibrator: Disable Vibrator
• No LED: Disable LED
Keep Alive Period: Maximum time between report in s
Stable Assert Delay: Time in s without motion to consider the TAG stable (and go to sleep when
enabled
Motion Assert Threshold: Accelerometer motion threshold
Discovery period: Interval in ms between discoveries. Do not go below 1000
LB threshold: Do NOT modify
Contact time: Minimal time in s of constant contact condition before triggering alarm. 0 to disable
and have immediate alarm
Expiration time: Time in ms during which one measurement is considered valid. Do not modify
Save time: Time in seconds without interaction with the device before considering the contact
terminated. Contact info is then stored in EEPROM when enabled
Debug Trace Level: Debug feature, Do not change
WIZZILAB Technical datasheet 14/20