User's Manual
WizFi360 User Manual
Notes
•
WizFi360 configured as a TCP server will disconnect from the TCP client that
does not communicate with it until timeout.
•
If AT+CIPSTO=0, the connection will never time out. This configuration is not
recommended
Example
AT+C IP MUX=1
AT+CIPSERVER=1,1001
AT+C IP STO=1 0
10.3.2.11. AT+PING Ping Packets
Command
AT+PING=<ip>
Response
+<time
> OK
or
ERROR
Parameters
<ip>˖string; host IP or domain name
<time>˖the response time of ping
Notes
AT+P IN G= ”192.168.4.1”
AT+P IN G= ”www.baidu.com”
10.3.2.12. AT+CIUPDATE Updates the Software Through Wi-Fi
Command
AT+C IUPDATE
Response
OK
10.3.2.13. AT+CIPDINFO Shows the Remote IP and Port with +IPD
Command
AT+CIPDINFO=<mode>
Response
OK
Parameters
<mode>:
轥ቖ
Ѣ
৲
ˈIP
ൠ൰
▶
0˖does not show the remote IP and port with +IPD
▶ 1˖shows the remote IP and port with +IPD.
Example
AT+C IP D IN FO=1
10.3.2.14. +IPD Receives Network Data
Command
(+CIPMUX=0)+IPD,<1en>[,<remote
IP>,<remote port>]:<data>
(+CIPMUX=1)+IPD,<link ID>,<len>
[,<remote IP>,<remote port>]