User manual

WIZ-600Wi User Manual
© Copyright 2008 WIZnet Inc. All rights reserved
37
Figure 22. Configuration Tool – Use Serial Converter
STEP 4> Execute ‘Device Terminal’ program included in the CD. ‘Device Terminal’ is the
combination program of serial terminal and network socket connection programs. It is developed
for more convenient test of serial to Ethernet. Configure the IP address and serial baud rate
according to the value of WIZ600Wi set in the STEP 3. If serial port of the testing PC is occupied
by another program, it can cause abnormal operation of Device Terminal program.
Device Terminal program is composed of upper Serial Terminal and lower Network Terminal. After
configuring serial, click “Open’ & buttons for program operation.
The module is configured as server mode at the ‘STEP3’. Input the module address ‘192.168.1.200
for IP address and6565 for the Port in the network terminal window. Click ‘Connect’ button for
the connection with module. If connection is completed, the status information Connected :
192.168.1.200:6565’ is displayed in the lower part of the program.