User's Manual
Technical parameters
1. Core: ARM Cortex M3 32bit
2. Communication: IEEE 802.15.4 USN Sub-GHz
3. 7-digit 7-Segment Display
4. 6times/sec Shot cycle
5. 3.6Volt Li-SoCl2(2/3AA 1650mA×2pcs)
6. 5years battery life(8times/day)
7. Working temperature -20~+85℃(-4℉~185℉)
8. Dimensions 36.5 × 58 × 27 mm
9. Mounting screws;
- M4 × 25mm Hex wrench bolt(Counter)
- M4 × 10mm Hex wrench bolt(Magnet)
General information
The counter is inactive upon delivery. After installing the WIZCoN on the mold’s
surface, the counter becomes automatically active. If the mode switch of the counter
is pressed, and then synchronize with the channel which is the setting on the
repeater only then communication is possible.
2. Connecting with the repeater
① Check the channel of the repeater for interworking between the counter
② Click add-button on the counter management tab in the repeater program.
③ Press the mode switch button for 2~3seconds to enter the channel setting
Mode.
④ Press the mode switch button shortly to move “LEAVE”.
⑤ Double-click the mode switch to select "LEAVE".
As a result, the antenna icon disappears.
⑥ Move to the channel of the repeater to be linked by pressing the mode switch
~
button shortly.
⑦ Press the allocated channel by pressing the mode switch button twice times
⑧ After the antenna icon appears on then the channel setting mode is terminated.
Press the button long.
4/8