Specifications
WITURACORPORATIONSDNBHD |WT‐1010S GSMAlarmPanelUserManualV1.1 13
Description:
First2digitsstandsfornonetworktimerangefrom00–59seconds.Default:6seconds.
Last2digitsstandsforthestayontimeofRelay2whennonetwork(00–59seconds),00meansRLY2willstay
ONpermanently.
Step14:InputSettings
The system has the function of sending the SMS alert message, call the administrator numbers or sound the
audiblesirenwhenInputtriggered.
Example:Toprogramtheunittogenerateanalertmessage,calltheadministratornumberandsoundthe
audiblesirenwheninput1triggeredyouwouldpress*24*11111#
Description:
FirstDigitstandsforgenerationofSMSalertmessagewhenInputTriggered.Default:0
SecondDigitstandsforgenerationofSMSalertmessagewhenInputRestored.Default:0
ThirdDigitstandsforsoundingtheaudiblesirenwhenInputTriggered.Default:0
ForthDigitstandsforcallingtheadministratorswhen
InputTriggered.Default:0
FifthDigitstandsforcallingtheadministratorswhenInputRestored.Default:0
Note:Thevalue1 meansenableand0meansdisable.AudiblesirenwillnotworkwhenACpoweris
unavailable
TocontinuetoenabletheInput2andInput3 functionspress*25*or
*26*
Note:PleaserefertoprogramminginstructionsviaSMSforeditingtheInputAlertmessages
Step15:ArmorDisarmtheSystem(ViaFixedLinePhone)
ToArmthesystem,youwouldpress*10*1#
ToDisarmthesystem,youwouldpress*10*0#
Note:OnlyinArmedmode,theWT‐1010ScangenerateSMSalerts,alarmsanddialingtheadministrator
numberswhentheinputstriggered,AutoTest,PSTNfailureorACfailure.
AlarmIndicator(Whenthe
Systemcallsyou):
WhenInput1triggered,itwillgenerates(Beep~)continuoussound
WhenInput2triggered,itwillgenerates(Beep~x2)continuoussound
WhenInput3triggered,itwillgenerates(Beep~x3)continuoussound
WhenACfailure,itwillgenerates(Beep~x5)continuoussound
WhenPSTNfailure,
itwillgenerates(Beep~x6)continuoussound
WhenAutoTest,itwillgenerates(Beep~~~)endlesssound