User manual

WT
-
101
0
C2
USER MANUAL
5.11 Output Settings
5.11.1 Activate Output Relay to Stay On for a Specific Time
To activate the output relay, you can send a text command via SMS specifying the
number of seconds the output should stay on to the unit. It is possible to set up to
maximum of 65,535 seconds
Text Command:
*RLY[N]#XXXXX
N stands for Output number 1 - 3
XXXXX stands for 5 digits value: The number of seconds (00000-65535)
For example, assume you want to turn on the output relay number 2 for 1 hour, you
would send the following SMS message to the unit.
*RLY2#03600
Return Message
RLY2#=03600
Sending the following SMS Message to unit would mean turn off the output relay
number 1.
*RLY1#00000
5.11.2 Enable/Disable the SMS Report when the Relay has turned off
The system has the function to send a SMS to the user when the relay has
turned off. It is possible to enable or disable this function by sending the
following SMS command to the unit.
Text Command:
*RLR[N]#X
N stands for Output number 1 3
X stands for ON (1) or OFF (0) value
Example:
When *RLR1#1 (Default) is applied, means when Relay 1 has turned off, it will send
a message to the programmable administrator number 1.
38
WT1010C2 – USER MANUAL – Rev.2.7 – Technical Support : Technical@witura.com
COPYRIGHT ©2008 WITURA CORPORATION SDN BHD