User manual

WT
-
101
0
C2
USER MANUAL
When *PSC?#1 is applied, it will dial the administrator/central station number when
PSTN failed.
When *PSC?#0 (Default) is applied, it will not dial the administrator/central station
number when PSTN failed.
To enable this function, you would send *PSC?#1 SMS command to the unit.
Return Message
PSC-ON
5.7.2 Enable/Disable the Function of Sending Alert Message when PSTN Failed
The system has the function to send alert message to the user in the event of PSTN
unavailable. It is possible to enable or disable this function by sending the following
SMS command to the unit.
Text Command:
*PSTN#X
X stands for ON (1) or OFF (0) value
When *PSTN#1 (Default) is applied, means it will send an alert message when PSTN
failed.
When *PSTN#0 is applied, means it will not send an alert message when PSTN failed.
To enable this function, you would send *PSTN#1 SMS command to the unit.
Return Message
PSTN-ON
5.7.3 Auxiliary PSTN Fail Output Facility via PIN15
In additional to the alarm and text alert on PSTN fail the system also has a second
permanent +V output continuously via PIN15 output of the unit which will remain
available for the period of PSTN unavailable. To turn On/Off this function, you can send
the following SMS command to the unit.
Text Command:
*PSOF#X
X stands for ON (1) or OFF (0) value
30
WT1010C2 – USER MANUAL – Rev.2.7 – Technical Support : Technical@witura.com
COPYRIGHT ©2008 WITURA CORPORATION SDN BHD