User manual
3
WT
-
101
0
C2
USER MANUAL
Wirin
g
Dia
g
ram A
(
Main Unit
)
WT1010C2 – USER MANUAL – Rev.2.7 – Technical Support : Technical@witura.com
COPYRIGHT ©2008 WITURA CORPORATION SDN BHD
GSM / GPRS
Module
PSTN
ISDN
General
Input for
Alarm
System
Connect the
antenna to
the GSM
Module
Connect to a
12V-24V
Control
Panel/Power
Supply
RS232 DB15 Port:
Connect to Inputs panel
& additional remote
controlling outputs
Alarm Transmission
via DTMF / SMS
Listening
Device
Connect to
the Internal
Battery
Connect to
the LCD
Wirin
g
Dia
g
ram B
(
DB15 Female Cable
)
GND (PIN1)
N/C
N/C
Auxiliary +V
Output when
PSTN Failed
(PIN
15
)
Audible Siren Output
(
PIN4
)
Input 1
(
PIN9
)
Input 2
(
PIN10
)
Output 2
(
PIN13
)
Permanent +V
Output when
power on
(PIN
8
)
Auxiliary +V
Output when
AC Failed
(PIN
7
)
Audible Siren
Ground
(
PIN5
)
N/C
Output 3
(
PIN14
)
Output 1
(
PIN12
)
Input 3
(
PIN11
)