WT-1010C2 G GS SM MA ALLA AR RM MS SY YS ST TE EM M User Manual W R R R W A P A O T T C U O O N S D N B H D WIIIT AC PO AT OR TIIIO TU CO RA UR OR ON RA RP NS SD DN NB BH HD D
WT-1010C2 USER MANUAL Sketch of the WT-1010C2 ANTENNA The antenna must be well connected before turn on the terminal POWER INDICATOR (RED) The indicator is illuminated when mains power is present NETWORK INDICATOR (GREEN) The indicator is illuminated when the terminal is connected to GSM Network Installation & Connection TEL PORT 1 (ALARM INPUT) Connect to Alarm Panel / also function as Phone Input ANTENNA PORT Connect the provided antenna to the Terminal TEL PORT 2 Connect to PSTN Line ON/OFF SWIT
WT-1010C2 USER MANUAL Wiring Diagram A (Main Unit) Connect the antenna to the GSM Module Connect to the Internal Battery Alarm Transmission via DTMF / SMS Connect to the LCD GSM / GPRS Module Listening Device ISDN PSTN General Input for Alarm System Connect to a 12V-24V Control Panel/Power Supply RS232 DB15 Port: Connect to Inputs panel & additional remote controlling outputs Wiring Diagram B (DB15 Female Cable) Audible Siren Output (PIN4) Audible Siren Ground (PIN5) N/C N/C Auxiliary +V Outp
WT-1010C2 USER MANUAL Please check the following packing list: Name WT-1010C2 Main Unit Telephone line DB15 (F) cable Power adapter 5m GSM terminal antenna User’s Manual Quantity 1 1 1 1 1 1 Unit set set set set set set Contents 1. Introduction to WT-1010C2 GSM Alarm System………………………………………………………………….….5 2. Main Features of the WT-1010C2….………….………………………………………………………………………………6 3. Installation Instruction...............................................................................................7 3.
WT-1010C2 USER MANUAL 1. Introduction to the WT-1010C2 GSM Alarm System The WT 1010C2 GSM Terminal is a wireless communicator for alarm and fire panels that uses the cell phone network (GSM) to transmit alarms and other panel event. The module checks the status of the PSTN line and in case the PSTN line becomes unavailable, the WT 1010C2 GSM emulate the line signal to the panel.
WT-1010C2 USER MANUAL 2. Main Features of the WT-1010C2 1. Panel compatibility - Allows any contact ID alarm panel to transmit alarms over GSM using the GSM voice channel 2. Works over the GSM cell phone networks Units can be used wherever there is cell phone coverage 3. Telephone line backup: WT-1010C2 give priority to the lowest cost network. WT-1010C2 uses the telephone line as the main transmission line and uses the GSM voice channel as backup 4.
WT-1010C2 USER MANUAL 7. Sends text messages to user programmable cell phone number (SMS): The WT-1010C2 can be programmed to send a SMS to a programmable cell phone number to notify the user that the PSTN line has been cut off or unavailable. 8. Wireless Listening Device – The WT-1010C2 has a built-in microphone that can be used for security and surveillance purposes. With this feature, it allows the user to observe the surrounding or the area of the unit. 9.
WT-1010C2 USER MANUAL 3.2) WT-1010C2 Inputs and Outputs Wiring Instructions ZONE1(RLY1), ZONE2 (RLY2), ZONE3 (RLY3) Remote Controlling Outputs Connect ZONE1, ZONE2 and ZONE3 to additional outputs for remote controlling. These open collector outputs can be turned on and off remotely through a SMS. Remote control will be reachable by sending a SMS with a certain command.
WT-1010C2 USER MANUAL Inputs and Outputs Wiring Diagram 3.3) Installing the SIM Card Note: Installing the SIM Card. Please be sure the initial 4 digit PIN code of SIM card is disabled. This can be done by placing it in an unlocked Mobile phone and first checking if the SIM requested any PIN code. If this is the case the PIN code can be disabled using the security settings on the phone. Proceed as follows: 1. Slide back the SIM door and lift it up 2.
WT-1010C2 USER MANUAL When the terminal is ready to use, it will display as below Power Signal WT-1010 Battery Functional 3.5) Dialing a number from the attached telephone set Connect to TEL1 After the GSM module is connected to the GSM network, an attached fixed line phone can be used to make calls. If you pick up the phone, you will hear a dial tone. Simply dial the number you want to call (as if you are dialing from a normal fixed line phone).
WT-1010C2 USER MANUAL 4. WT-1010C2 Configuration Instructions (Via Voice) 4.1 Introduction The WT-1010C2 can be programmed manually by a connected normal telephone. Connect to TEL1 Note: Before commencing programming it is advisable to read the below programming setting instructions thoroughly. To start with programming, user must plug-in a normal single line phone to TEL1 (Port 1) 1) Enter Programming Mode Pick up the handset or press hands free, press **123456# to enter programming mode.
WT-1010C2 USER MANUAL HAND FREE… Programming Mode 2) Reset the Main Unit To reset the unit, you can press *15* to proceed. REST– ON&OFF: REST– ON&OFF: 1 To reset the unit simply press 1# To turn back simply press 0# REST– ON&OFF: 1 OK Note: It is advised that you should reset the WT-1010 unit before proceeding to the below programming section.
WT-1010C2 USER MANUAL TEL: OK 1# Number programmed successfully You may continue to program administrator number 2, 3, 4, 5, 6, 7 and 8 by pressing *2* , *3* , *4* , *5* , *6* , *7* or *8* Warning: The administrator number must be program into the WT-1010 unit in order to use SMS programming mode. 4) Deleting the Administrator/Central Station Number Example: To delete the programmed administrator number 1, you can press *1* to proceed.
WT-1010C2 USER MANUAL ANY – ON&OFF: 1 To turn on this function simply press 1# To turn off this function simply press 0# ANY – ON&OFF: 1 OK 6) Changing the Login Password To change the 6 digits login password, you can press *0* to proceed. NEW PASSWORD: NEW PASSWORD: 654321 Input new password and ended with # NEW PASSWORD: 654321 OK 7) Time Setting To setup time, you can press *16* to proceed. TIME: TIME: : : 08 : 30 : 00 Example: To set the time at 8.30am WT1010C2 – USER MANUAL – Rev.2.
WT-1010C2 USER MANUAL Simply input digits and ended with # TIME: 08 : 30 : 00 OK 8) Enable/Disable the feature of Password Request when Login the System By default every time ringing the system, it will prompt you to input a login password to gain access to the system. To enable/disable this function, you can press *13* to proceed.
WT-1010C2 USER MANUAL SECT: 11111111 Example: To turn on this function for all recipients Simply input 11111111# SECT: 11111111 OK Note: The input for this setting is an 8 digits value: ON (1) or OFF (0) only. Each of them represents administrator 1 - 8 10) Setting the Account Number for Event Reporting When PSTN failure, AC failure or Auto Test, the WT-1010C2 will dial the programmable central station number and transmit the account number along with Contact-ID to the central station.
WT-1010C2 USER MANUAL 11) Setting the Burst On and Burst Off time of DTMF tones The Burst ON and Burst OFF timing of the sending Contact-ID can be adjust with the below command. To set the Burst on and Burst off time, press *37* to proceed.
WT-1010C2 USER MANUAL Simply input digits and ended with # DSTM: 12 : 00 : 00 OK 13) Enable/Disable the function of dialing the programmed Administrator number for Auto Test To turn on this function, you can press *27* to proceed. DTIMEC – ON&OFF: DTIMEC – ON&OFF: 1 To turn on this function simply press 1# To turn off this function simply press 0# DTIMEC – ON&OFF: 1 OK 14) Enable/Disable the generation of SMS Report for Auto Test To turn on this function, you can press *28* to proceed.
WT-1010C2 USER MANUAL DTIMEM – ON&OFF: 1 OK 15) Setting for Calling a group of administrator numbers To program the unit to dial a certain group of numbers when PSTN/AC failed or Auto Test, you can press *29* to proceed. CALL: CALL: 5 Example: Setting the unit to dial the first 5 administrator numbers Simply press 5# CALL: 5 OK 16) “PSTN Failure” Setting To do this setting, you can press *30* to proceed.
WT-1010C2 USER MANUAL PST: ME: 1 OU: 1 CA: 1 AL: 1 OK Note: “ME” stands for generation of SMS when PSTN failed “OU” stands for generation of pulse (+V) when PSTN failed “AL” stands for sounding the audible alarm when PSTN failed “CA” stands for calling the administrators when PSTN failed Value: ON (1) or OFF (0) 17) “AC Failure” Setting To do this setting, you can press *31* to proceed.
WT-1010C2 USER MANUAL IN1: OP: CL: AL: CA: IN1: OP: 1 CL: 1 AL: 1 CA: 1 Example: Setting the input 1 to generate an SMS, call the administrators and sound the audible alarm when it triggered.
WT-1010C2 USER MANUAL RLY1: 00050 RE: 1 OK Note: “ RE:” stands for generation of SMS when relay off, value: ON (1) or OFF (0) You may continue to activate relay 2 or relay 3 by pressing *22* or *23* 20) Setting the Waiting Time for Engaged Call In the event the administrator has not answered the call or engaged, it could take a while for the WT-1010C2 to call the next number. You can shorten the time for every call by programming the waiting time. Press *12* to proceed.
WT-1010C2 USER MANUAL NEW AREA: 03 Enter area code and ended with # NEW AREA: OK Area code programmed successfully 22) Setting the Function of Adding Area Code when Transmitting an Alarm To turn on/off this function, you can press *14* to proceed.
WT-1010C2 USER MANUAL Example: To set the delay time at 7 seconds Simply press 00007# DTTRANSMIT: 00007 OK 24) Setting the Alarm Time for Audible Alarm To set the alarm time for audible alarm, you can press *33* to proceed.
WT-1010C2 USER MANUAL 26) Inquire the status of the Recipients that will receive Alert Messages To inquire the status of the recipients, you can press *19* to proceed. RECIPIENTS: 11111111 The status will be displayed on screen Press # to turn back 27) Inquire the signal strength To inquire the signal strength, you can press *20* to proceed. CSQ <23> The signal strength will be displayed on screen Press # to turn back WT1010C2 – USER MANUAL – Rev.2.7 – Technical Support : Technical@witura.
WT-1010C2 USER MANUAL 5. WT-1010C2 Configuration Instructions (Via SMS) You can program the WT-1010C2 via SMS commands using your phone. Any programming command sent by SMS must be in CAPITAL letters. The fields between square brackets are parameters; do NOT enter the square brackets. When you send a command, you will receive the answer for the first time even if your GSM number is not in the administrator list. This happens because the WT-1010C2 recognizes any GSM number as administrator and answers to it.
WT-1010C2 USER MANUAL Text Command: *ANY?#X X stands for ON (1) or OFF (0) value When *ANY?#1 is applied, means only administrator can access the system When *ANY?#0 (Default) is applied, means any person can access the system To activate this function, you would send *ANY?#1 SMS command to the unit. Return Message ANY-ON 5.3 Time Setting To set the time, you can send the following SMS command to the unit. The time is entered in 24 Hour format.
WT-1010C2 USER MANUAL 5.4 Turn Off the feature of Password Request when Accessing the System By default every time calling the system, it will prompt you to input a login password to gain access to the system. To turn off this feature, you can send the following SMS command to the unit. Text Command: *PWOF#X X stands for ON (1) or OFF (0) value When *PWOF#1 (Default) is applied, you can access the system with a login password to program administrator number or changing the login password.
WT-1010C2 USER MANUAL *ACCT#9999 Return Message ACCT:9999 Note: Please refer to page 43 for Contact-ID Protocol for WT-1010C2 5.6 Setting the Burst On and Burst Off time of DTMF tones The Burst ON and Burst OFF timing of the sending Contact-ID can be adjust by sending the following SMS command to the unit.
WT-1010C2 USER MANUAL When *PSC?#1 is applied, it will dial the administrator/central station number when PSTN failed. When *PSC?#0 (Default) is applied, it will not dial the administrator/central station number when PSTN failed. To enable this function, you would send *PSC?#1 SMS command to the unit. Return Message PSC-ON 5.7.2 Enable/Disable the Function of Sending Alert Message when PSTN Failed The system has the function to send alert message to the user in the event of PSTN unavailable.
WT-1010C2 USER MANUAL When *PSOF#1 is applied, means it has +V output via PIN15 when PSTN failed. When *PSOF#0 (Default) is applied, would mean turned off this function. To enable this function, you would send *PSOF#1 SMS command to the unit. Return Message PSOF-ON 5.7.4 Turning the Audible Alarm On/Off for PSTN failure The system has the function to sound the connected audible siren when PSTN failed. This output is available on the connection PIN4 and ground on the main board.
WT-1010C2 USER MANUAL When *ACCA#0 (Default) is applied, it will not dial the administrator/central station number when AC failed. To enable this function, you would send *ACCA#1 SMS command to the unit. Return Message ACCALL-ON 5.8.2 Enable/Disable the Function of Sending Alert Message when AC Failed The system has the function to send alert message to the user in the event of power failure. It is possible to enable or disable this function by sending the following SMS command to the unit.
WT-1010C2 USER MANUAL Return Message ACALARM-ON 5.8.4 Auxiliary Power Down Output Facility via PIN7 In additional to the alarm and text alert on AC fail the system also has a second permanent +V output continuously supplied from the battery backup via PIN7 output of the unit which will remain available for the period of AC unavailable. 5.9 “Auto Test” Settings 5.9.
WT-1010C2 USER MANUAL When *DTM?#1 is applied, it will send the status of the system via SMS to the programmable administrator/central station number at the programmed report time interval. When *DTM?#0 (Default) is applied, it will not send the status of the system. To enable this function, you would send *DTM?#1 SMS command to the unit. Return Message DTIME-ON 5.9.3 Editing the Message Contents of SMS Report (Up to 50 Characters) The message contents can be edited and programmed up to 50 characters.
WT-1010C2 USER MANUAL When *DTC?#1 is applied, it will dial the programmable administrator/central station number at the programmed report time interval. When *DTC?#0 (Default) is applied, it will not dial the administrator/central station number. To enable this function, you would send *DTC?#1 SMS command to the unit. Return Message DTCALL-ON 5.10 Input Settings 5.10.
WT-1010C2 USER MANUAL *INR[N]#X N stands for Input number 1 – 3 X stands for ON (1) or OFF (0) value Example: When *INR1#1 is applied, means when Input 1 has triggered (Open/High Pulse), it will send an alert message to administrator/central station number 1. When *INR1#0 (Default) is applied, means when Input 1 has triggered (Open/High Pulse), it will not send any alert message to administrator/central station number 1. To enable this function for input 1, you would send *INR1#1 SMS command to the unit.
WT-1010C2 USER MANUAL 5.10.4Editing the Inputs Alert Messages (Up to 50 Characters) The Input Alert Message can be edited and programmed up to 50 characters. You can change the displayed text by sending the following commands by SMS message to the unit. Note: Only support normal abc/ABC English text, no special characters.
WT-1010C2 USER MANUAL 5.11 Output Settings 5.11.1 Activate Output Relay to Stay On for a Specific Time To activate the output relay, you can send a text command via SMS specifying the number of seconds the output should stay on to the unit.
WT-1010C2 USER MANUAL When *RLR1#0 is applied, means when Relay 1 has turned off, it will not send any message to the programmable administrator number 1. To enable this function for output 1, you would send *RLR1#1 SMS command to the unit. Return Message RLR1-ON 5.12 Setting the Waiting Time for Engaged Call In the event the administrator has not answered the call or engaged, it could take a while for the WT-1010C2 to call the next number.
WT-1010C2 USER MANUAL Return Message AREA-OK 5.14 Setting the Function of Adding Area Code when Transmitting an Alarm The system has the function of adding area code automatically when dialing the number from the alarm panel. It is possible to enable or disable this function by sending the following SMS command to the unit. Text Command: *AROF#X X stands for ON (1) or OFF (0) value When *AROF#1 is applied, it will add the programmed area code in front every time it dials the number from the alarm panel.
WT-1010C2 USER MANUAL *DAIL-TIME#=00007 5.16 Setting the Alarm Time for Audible Alarm (Default: 600 seconds) The alarm siren can be set to determine how long the siren will remain active and this can be done by sending the following SMS command to the unit. Text Command: *ALTM#XXXXX XXXXX stands for 5 digits value: The number of seconds (00000-65535) Example: When *ALTM#03600 is applied, means the audible alarm will sound for 1 hour when triggered Return Message *ALTM#3600 5.17 Miscellaneous Settings 5.
WT-1010C2 USER MANUAL 5.17.3 Checking Signal Strength To check the signal strength of the unit, you can send the following SMS command to the unit. Text Command: *CSQ?# 5.17.4 Inquire Time Status To check the time status, you can send the following SMS command to the unit. Text Command: *ASTM# 5.17.5 Sound the Audible Alarm manually It is possible to sound the alarm manually by sending the following SMS command to the unit, which remain active for the period of time set.
WT-1010C2 USER MANUAL 5.17.7 Setting for Dialing a group of administrator numbers when PSTN/AC failed or Auto Test To program the unit to dial a certain group of numbers when PSTN/AC failed or Auto Test, you can send the following SMS command to the unit. Text Command: *CALL#X X stands for group number: 1 – 8 Example: When *CALL#5 is applied, means it will dial the first 5 administrator numbers. 5.17.
WT-1010C2 USER MANUAL 6. Digital Communication Standard - Contact ID Protocol for WT-1010C2 Objectives a) Provide information regarding events that are occurring on a customer’s premises. This information should be in a form that can easily be interpreted by a central station operator. b) Spend minimum practical time on line per transaction, to minimize the number of receivers required to handle the traffic and minimize the time the line is seized and not available to the customer.
WT-1010C2 USER MANUAL • A burst of 1400 Hz. ±3% tone with a duration of 100 msec. ±5% • A pause of 100 msec. ±5% • A burst of 2300 Hz. ±3% tone with a duration of 100 msec. ±5% Note: Transmitters shall accept a frequency error of at least ± 5% to ensure backcompatibility with older receivers. Message Blocks A Message Block is sent by the TRANSMITTER for each message in the transmitter’s message queue. Each message block contains sufficient information to report an event in the system.
WT-1010C2 USER MANUAL Data Transmission Frequencies – Standard DTMF Signaling Digit Low Tone High Tone Digit (Hz.) (Hz.
WT-1010C2 USER MANUAL Note: Transmitters shall accept a frequency error of at least ± 5% to ensure back compatibility with older receivers Maximum Number of Attempts The transmitter shall make up to 4 attempts to deliver a message before hanging up and redialing. The attempts counter is reset each time a valid kissoff signal is received. 7. Technical Specifications 1. Environment temperature: 0~+50℃ 2. Relative humidity: 10%~95% 3. Air pressure: 86~106kpa 4. Environment yawp: ≤60dB (A) 5.
WT-1010C2 USER MANUAL Warranty Witura Corporation Sdn Bhd guarantees all WT-1010C2 GSM Fixed Wireless Terminal against defective parts and workmanship. Witura Corporation Sdn Bhd shall, at its option, repair or replace the defective equipment upon the return of such equipment to any Witura branch.