User manual

32
WT-1010C2 USER MANUAL
WT-1010C2
USER MANUAL
Rev.3.9
Technical Support: Technical@witura.com
COPYRIGHT ©2011
WITURA CORPORATION SDN BHD
Text Command:
*RLY[N]#XXXXX
N stands for Output number 1 - 3
XXXXX stands for 5 digits value: The number of seconds (00000-99999)
For example, assume you want to turn on the output relay number 2 for 1 hour, you
would send the following SMS message to the unit.
*RLY2#03600
Return Message
*RLY2#=03600
Sending the following SMS Message to unit would mean turn off the output relay number
1.
*RLY1#00000
To activate the output relay to stay on indefinitely, you can send the following text
command via SMS to the unit.
Text Command:
*RLY[N]#ON
N stands for Output number 1 - 3
For example, assume that you want output relay number 1 to stay on indefinitely, you
would send the following SMS message to the unit.
*RLY1#ON
To switch off the output relay, you can send the following text command via SMS to the
unit.
Text Command:
*RLY[N]#OFF
N stands for Output number 1 - 3
For example, to switch off output relay number 2, you would send the following SMS
message to the unit.
*RLY2#OFF
6.6.2 Activate Output Relay to Stay On Indefinitely