Description:
“OP” stands for generation of SMS when input triggered (Open). Default: 0
“CL” stands for generation of SMS when input triggered (Close). Default: 0
“AL” stands for sounding the audible alarm when input triggered. Default: 0
“CA1” stands for calling the administrators when input triggered (open). Default: 0
“CA2” stands for calling the administrators when input triggered (close). Default: 0
Value: ON (1) or OFF (0)
Note: Audible Alarm will not work when AC power is unavailable
You may continue to activate Input 2 and Input 3 functions by pressing *25* or *26*
Note: Please refer to programming instructions via SMS for editing the Input Alert messages
To arm the system, you can press *10* to proceed.
Example: To arm the system simply press 1#
To disarm the system simply press 0#
System armed successfully
Note: In Armed mode, the WT-1010C2 can generate SMS alerts, alarms and dialing the
administrator numbers when the inputs triggered, Auto Test, PSTN failed or AC failed.
Alarm Indicator (When dialing the Administrator numbers):
When Input 1 triggered, it will generates (Beep~) continuous sound
When Input 2 triggered, it will generates (Beep~ x 2) continuous sound
When Input 3 triggered, it will generates (Beep~ x 3) continuous sound
When AC failed, it will generates (Beep~ x 5) continuous sound
When PSTN failed, it will generates (Beep~ x 6) continuous sound
When Auto Test, it will generates (Beep~~~) endless sound
ARM OR DISARM
ON&&OFF:
ARM OR DISARM
ON&&OFF: 1
ARM OR DISARM
ON&&OFF: 1 OK
Step 14. Arm and Disarm the System (Via Fixed Line Phone)