User manual
21
WT-1010C2 USER MANUAL
WT-1010C2
–
USER MANUAL –
Rev.3.9
–
Technical Support: Technical@witura.com
COPYRIGHT ©2011
WITURA CORPORATION SDN BHD
Note: Please refer to programming instructions via SMS for editing the message content
of Auto Test
Step 9.7 Setting the Burst On and Burst Off time of DTMF tones
The Burst ON and Burst OFF timing of the sending Contact-ID can be adjust
with the below command. To set the Burst on and Burst off time press *37*
to proceed.
Example: To set the Burst On time at 50~60ms (3)
and Burst Off time at 10~20ms (1)
Simply press 31#
Description:
Value: 1 stands for 10~20ms
Value: 2 stands for 20~40ms
Value: 3 stands for 50~60ms
Value: 4 stands for 60~80ms
Value: 5 stands for 80~100ms
Warning! The WT-1010C2’s Contact ID Protocols are complied with the Digital
Communication Standard of Ademco. You are advised to go through the Digital
Communication Standard here www.smartelectron.ru/files/DC-05_Contact_ID.pdf
before proceed with this setting.
DTMF BURST TIME
ON TM: OFF TM:
DTMF BURST TIME
ON TM:3 OFF TM:1
OK