Replacing the front glass plate window:
To remove the glass plate you must remove part of the flue gas baffle and the primary air baffle. First,
remove the first part of the lower flue gas baffle (as described in the Cleaning Instruction section of the
manual).
Then unscrew the primary air baffle screw and take this off from the vertical Vermiculite plates. Now
remove the bottom plate of the fire chamber and unscrew and remove the pilot air supply. After that you
can unscrew the screws of the upper and lower glass retaining strips. First remove the upper strip and
then the lower strip. Afterward the old glass can be removed. Before you place the new glass, make sure
that the new gaskets are correctly positioned. After installing the new glass plate, make sure that the
screws are tightened evenly (with caution) in alternating order so the glass will not break under too much
pressure.
Upon completion of the glass assembly, first re-insert the pilot air inlet and then the bottom plate of the
fire chamber. Next, install the air baffle of the primary air. The procedure is as follows:
1. Rest the two notches of the primary air baffle up on the lateral, vertical Vermiculite plates.
2. Push the guide plate up to glass plate.
3. Now the air baffle can be screwed on.
If you placed the air baffle as described, then the primary air is led properly in front of the glass plate and
thus the glass is kept clean as well as ensuring a clean burn. After replacing the air baffle you can then