User manual
Version: 10/09 Page 3
Safety and Environmental Testing
The H530 Insert/Firebox for the Klassic has been tested by OMNI-Test Laboratories, Inc. of Portland,
Oregon and is listed to UL 1482 and ULC S628. It is also EPA certified.
Features and Items Included
Your KLASSIC has a built-in convection system, so it creates air circulation in the room to spread the
heat faster and more evenly.
The stove has a small "cool" handle, which enables you to open the door without the use of a glove
(however, always use caution when touching areas where HOT surfaces are located).
Included in the firebox are:
• a thermometer
• an oven mitt
• an easy to use lighter
• a can of touch-up paint (Remove from the stove!)
2. INSTALLATION
Precautions
I
F THIS STOVE IS NOT INSTALLED PROPERLY, A HOME FIRE MAY RESULT. TO REDUCE THE RISK, PLEASE
CAREFULLY FOLLOW THE DIRECTIONS FOR INSTALLATION.
First, the stove must be installed according to the directions in this manual. Consult your local Building
Inspector or Fire Marshall before installation about restrictions and installation inspection requirements in
your area. Also, in some areas a "special permit" is required.
Not for use in a mobile home.
If utilizing an existing chimney, it is suggested that you have a professional mason or stove installer do a
complete check-up of your chimney, liner, and flue.
In order for the stove to work and draw properly, sufficient air is important! Be especially aware of any
mechanical fans (e.g. kitchen or bathroom) that may affect the proper draw.
When installing the stove, the heat distribution to other rooms should be taken into consideration.
In addition, make sure that the floor and sub-flooring is designed to carry the extra weight of the stove.
A floor plate of non-combustible material (tempered glass floor plates are acceptable) must cover under
the stove and extend 16" (41 cm) (18" (45 cm) in Canada) in front of the stove door, 8" (20 cm) beyond
the sides of the fuel-loading door, and under the pipe and 2" (5 cm) beyond each side for back venting.
In Canada, the 8" (20 cm) floor protection is required beyond the sides of the stove and in the back of the
stove (0" in the back for the US).
The Klassic has a heating capacity of approximately 1,076 ft
2
(100m
2
) based on a standard ceiling
height.