Specification Sheet

Table Of Contents
WT901 | Datasheet v20-0702 | http://wiki.wit-motion.com/english
- 34 -
5.2.35 Set alarm of module
1. Setting minimum value of X-axis angle
For example, FF AA 5A E4 F8 sets the minimum X-axis angle to -10 degrees.
2.Setting maximum value of X-axis angle
For example, FF AA 5B 1C 07 sets the maximum X-axis angle to 10 degrees.
3. Setting minimum value of Y-axis angle
For example, FF AA 5E E4 F8 sets the minimum Y-axis angle to -10 degrees.
4.Setting maximum value of Y-axis angle
For example, FF AA 5F 1C 07 sets the maximum Y-axis angle to 10 degrees.
5.Setting of confirm time
For example, the confirmation time set by FF AA 68 00 00 is 0ms.
6.Setting of hold time setting
For example, the hold time set by FF AA 59 64 00 is 100ms.
7.Setting of alarm level
For example, the alarm level set by FF AA 62 00 00 is 0.