User's Manual
Table Of Contents
MTK952 User Manual
rev.06
13
TX configuration (only for MTK952N with option MS)
This parameter permits to use the transmitter in Master or Slave configuration.
When the MTK952N is in Master configuration, the signal is transmitted as a normal MTK952N
(without MS option) but at the same time, the signal is sent also in the M-S I/O BNC connector at
0dBm (without amplification).
When the MTK952N is in Slave configuration, everything that is before the power stage is excluded
and the device take as input the signal that enter in the M-S I/O BNC connector, amplifies the
signal (at the power set on the MTK952N-Slave) and transmits it.
MTK952N is able to detect a signal in the range -6dBm ÷ +6dBm (than the 0dBm sent from the
MTK952 Master).
Example of configurations: iso-frequency areas
MTK952N
Master conf.
MTK952N
Slave conf.
MFL-TT--
MFL-RR--
Fiber optic cable
up to several tens of kilometers
(depending on the fiber)
Area 3
Area 4
Audio input
MTK952N
Slave conf.
MTK952N
Master conf.
Coaxial cables
up to several tens of meters
(depending on the cable)
Area 1
Area 2
Audio input