User manual

MFLUserManual
rev.02

RXLinkmenu
FromtheMainscreen,pushingtherotaryknob,it’spossibletoenterontheselectionscreenandthen,pushingtheupper
rightbuttononthedesideratereceivermodule,it’spossibletoenterontheRXLinkmenu:
Status:statusofthetransmitter
(defaultON)
Mode:workingmodeselection:
ANTforremoteantennareception
IFBforremoteintercominisofrequencyareasapplications
(defaultANTmode)
Gain:Settablegainfrom‐13.5to18.0dBwithstepof0.5dB.(typ.)
(default0.0dB)
Failsafe:ToenableordisabletheFailsafeoption
(defaultdisabled)
Opticalpower:Thisparametershowthereceivedopticalpower
Opticalpwr.corr.:(opticalpowercorrection)thisoptioncanbeenabledtoensurethat,in
caseinchangesofopticalpower,theoverallgainofthesystemremainsunchanged(tokeep
thegainintheRFoutputat0dB).
(defaultON)
Receiverparam:hereit’spossibletoseeallthereceiverparameters:
Example
ID IDofthereceiver ORM001
Serial Serialnumberofthereceiver T1841930
Optrxpwrlimits Opticalpowerworkinglimits 0.3mW3.0mW
Temperature Workingtemperature NA
Offsetgain Offsetgainofthemodule 0.0dB
Wavelength Opticalwavelength 1550nm
Lifetime Lifetimeofthedevice 3d‐00h‐49m
