MTH400 User Manual Wideband Wireless Professional Handeld Transmitter SN: ________________ Rev.01 (rif. FW 1.10.
MTH400 User Manual Rev.01 INTRODUCTION MTH400 is a professional radio microphone especially designed for broadcast/high quality applications. MTH400 is composed by 3 detachable parts: • • MIC Head (available with cardioid/hypercardiod polar pattern). • MIC Antenna, made with fibreglass reinforced housing and with a “Wireless power switch” (fig. 3). “MIC Antenna” is fastened to body with 2 anvils and a micro-connector.
MTH400 User Manual Rev.01 SAFETY INSTRUCTION Read this safety instruction and the manual first Follow all instructions and information. Do not lose this manual. Do not use this apparatus under the rain or near the water. Do not install the apparatus near heaters or in hot environments, do not use outside the operating temperature range. Do not open the apparatus, only qualified service technician are enabled to operate on it.
MTH400 User Manual Rev.01 POWERING UP Move the wireless power switch (fig. 3) in upper position (towards MIC body) to activate wireless transmission: a green LED lights up (blinking when battery is low!). SETUP CONTROL Open MIC Body to access the “display and controls” area (fig. 1): A. B. C. D. Graphics Display (OLED) Channel selection buttons (ch) MIC gain setup buttons (gain) 3 position selector (up / down / click) C A D B Fig.
MTH400 User Manual Rev.01 OLED POWER DOWN (OLED IS IN ON CONDITION) Pushing and holding selector (click) > 2 sec, display is turned off. Display turns off automatically after 15 sec, unless in menu or in
MTH400 User Manual Rev.01 menu This menu can be entered by scrolling selector or using quick gain setup button (gain). The first AUDIO menu allows to set the AF Gain from -20dB to 40dB. To help proper audio gain setting, an audio bar is supplied (with peak hold bar) TRY TO SETUP TO HAVE A MAX PEAK HOLD BAR CLOSE TO 6dB.
MTH400 User Manual Rev.01 The following table sums up which parameters can be set and the related range settings. MENU PARAMETER MEANING RANGE SETTINGS TUNING CH GR Freq Channel Group Frequency AUDIO AF Gain Noise R.
MTH400 User Manual Rev.01 WISYCOM IR PROGRAMMER (VER. 1.3.1.1 AND ABOVE) Wisycom IR Programmer allows to read, modify and update the MTH400 device configuration. It is necessary to install Wisycom IR Programmer (version 1.3.1.1 or above) WARNING: If it is the first installation and Wisycom USB driver has not already installed in the PC, install the USB driver (run C:\Program Files (x86)\Wisycom\MTP&MTH Infrared Programmer (TX)\Drivers\ DriverInstaller.
MTH400 User Manual Rev.01 10 different configurations are available: • FACTORY configuration is a locked configuration: no parameter can be changed. USER configuration is the only configuration that can be saved using the OLED display (see menu). Note: It is not possible to change the name of this configuration. Other 8 configurations where the user can change both the name and the values of all parameters.
MTH400 User Manual Rev.01 TUNING FREQUENCIES PANEL With the Tuning Frequencies panel the user can select a frequencies group (0÷39) and for each one execute the following operations: - modify the Group’s Name lock and/or hidden the group for each channel (0 ÷59) of the selected group: change the frequency value and the related status (locked/hidden) (in the center grid frequency) The SAVE button, at the top of the panel, save the changes of the group selected (name group, lock/hidden group).
MTH400 User Manual Rev.01 Using the LOAD/SAVE button, at the bottom of the panel, it is possible to load/save the frequencies for the selected group from/to a .wdf file. To save the frequencies of all the groups click to the related button above. The legacy option save the channels without the hidden/lock info.
MTH400 User Manual Rev.01 PRESETS PANEL The Preset panel allows to manage all the 10s available configurations. For each configuration it is possible to set the name and all the parameters value except for FACTORY and USER configurations (see table below). PRESETS: NAME* LOCK/DON’T CARE PARAMETERS VALUE FACTORY USER √ OTHERS √ √ √ √=change is allowed * Be careful to write a meaningful name for the preset because the name will appear on the settings list of the device menu! Please, avoid empty names.
MTH400 User Manual Rev.01 FILE MENU Using a file menu at the top left of the panel it is possible to load/save all the configuration values of the device to/from a .wcf file (Wisycom Configuration File). Save a .wcf file With an infrared device correctly connected, select File->Save User Configuration and select the destination file. Load a .
MTH400 User Manual Rev.01 TECHNICAL SPECIFICATIONS Switchable channels Switching window Frequencies Frequency stability Temperature range Max RF power Spurious emissions Modulation Nominal deviation Telemetry feature AF input connection AF input level Max.
MTH400 User Manual Rev.01 In compliance with EMC: EN 301489-1/-9 Europe Radio: EN 300422-1/-2 Safety: EN 600065 USA PART 74 FCC-ID: POUMTH400 Limited to 698 MHz Note: The above technical specifications refer to the MTH 400 “transmitter” section. The acoustic specs are relevant to the microphone-head used. The MTH 400 transmitter complies with ETS 300 422.
MTH400 User Manual Rev.01 MANUFACTURER DECLARATIONS In compliance with the following requirements RoHS Directive (2002/95/EC) WEEE Directive (2002/96/EC) Please dispose of the diversity transmitter at the end of its operational lifetime by taking it to your local collection point or recycling center for such equipment Battery Directive (2006/66/EC) The supplier batteries or rechargeable batteries can be recycled. Please dispose of them as special waste or return them to your specialist dealer.
MTH400 User Manual Rev.
ITALY ONLY Obblighi di informazione agli utilizzatori ai sensi dell’art. 13 del Decreto Legislativo 25 luglio 2005, n.
MTH400 User Manual Rev.
MTH400 User Manual Rev.01 WISYCOM srl Via Spin 156 I-36060 Romano d’Ezzelino Italy Tel. +39 -0424 -382605 Fax +39 - 0424 - 382733 www.wisycom.com e-mail: sales@wisycom.