Data Sheet

SWA54 Module Datasheet Rev 1.2
8
1 Electrical, Audio and Timing Specifications
1.1 Module ESD spec.
CONDITION
MIN
MAX
ESD Contact HBM
4kV
----
Notes:
1) HBM = ESD Human Body Model; C = 150pF, R = 330Ω ; non-operational mode.
1.2 Recommended Operating Range
PARAMETER
MIN
TYP
MAX
UNIT
VDD, +5V Supply pin voltage 4.5 5.0 5.5 V
Ambient Temperature (T
A
) 0 55 ºC
RESET pin hold time 10 msec
Power Supply Rise Time (to 4.5V) 0 10 msec
1.3 Electrical Characteristics DC Characteristics
Operating Conditions: VDD = 4.5 to 5.5V, TA = 0°C to +55 °C, RF Freq = 5150-5250;5725-5875MHz, measured relative to the RF balun
single-ended I/O. Typical specifications at T
A = 25°C, VDD = 5.0V
5V.
PARAMETER CONDITIONS MIN TYP MAX UNIT
Supply Current (IVDDA)
RX mode (continuous RX)
Link mode ( for SWA54 TX)
Link mode ( for SWA54 RX)
TX mode (continuous TX); Pout=+14dBm
89
270*a
130*a
350*a
mA
mA
mA
CMOS I/O Logic Levels 3.3V I/O
Input Voltage Logic Low, VIL
0.6 V
Input Voltage Logic High, VIH
VDDIO
-0.6
V
Output Voltage Logic Low, VOL
0.3 V
Output Voltage Logic High, VOH
VDDIO
-0.3
V
*a : This is DCRMS current consumption value. If customer want to implement OCP(over current protection) for SWA54,
please consult with WNC for proper setting and design.