Installation Guide

9
Normal Internal Use Confidential Restricted Confidential
1
Screwing gland
Seal gasket
Seal cap
Clamp ring
Wrench fix the screwing gland
2
Torque: 25~27kgf-cm
Put the gasket and clamp ring in
4
Torque: 15~25kgf-cm
5
Wrench fix the seal cap
3
5
J-Pole Installation & cable dimension constraint
Finish the waterproof cable gland setup as below.
Note: For ODU installation, please notice that cable size
should not too big due to dimension constraint of cable gland.
Cable diameter: 6.5~9mm
Access diameter:
ϕ19mm Max
Diameter
< ϕ19mm