Installation Guide
25
□ Normal □ Internal Use ■ Confidential □ Restricted Confidential
4.8
T8
7.5
Take out IDU Device from ODU
• Take off the ODU from the bracket(wall/pole/J-
pole) and put it on a plat base.
• Release 14 waterproof screws, then the
heatsink could be took off.
Please follow the sequence of removing screw,
see in next page.
Waterproof
Screws x14pcs
• Take off heatsink, and the IDU could be took out.
• Need pull force exert on heatsink to remove it, because
thermal jelly stick it tightly.
Heatsink
Screw type: M2.5
Screw Head : T8
Unit: mm
2
1
Thermal jelly
Stick tightly
Pull up