User's Manual
User manual of 3G SEP EVDO module
Page 21
awakened with any character received on the UART. However, to be
sure to awaken the module, the “0x00” character must be sent.
The main interest of the AT+KSLEEP=0 mode is to be able to forbid the sleep
mode from using the DTR signal.
AT+KSLEEP=2
In this mode the sleep state is never authorized in any DTR state.
Detailed descriptions of these modes are given in.
2.9.3 Power consumption
The power supply input of ranges from 3.4V to 4.2V and 4V is nominal.
All measurements in the communication mode are done at the maximum RF
power transmission (PCL max).
-30°C 25°C +85°C
Typ. Typ. Max Typ.
Off mode 50 µA 100 µA
Stand-by mode – connected to the
network (cell power -55dBm/1.23MHz)
150mA 150mA 200mA 150mA
C2K 1X
TX: Maximun power
All band 700mA 700mA 780mA 700mA
EVDO data mode
TX: Maximun power
All band 680mA 680mA 750mA 680mA