User`s guide
32-English
Your thermostat can be configured to change the temperature setting based on energy alerts sent by your energy
provider over the network. The Setback and Cycle screen allows you to set the amount of change.
Access the Setback and Cycle screen by pressing [Energy] on the Home screen, and then pressing
[Setbacks] on the Energy screen.
Turn the Scroll Wheel to adjust the temperature Setback
setting for the corresponding Time of Use (TOU) level.
Setback is adjusted in one degree increments.
When the desired Setback is displayed for the
corresponding Time of Use level, press the Scroll Wheel
to highlight the Cycle setting.
Turn the Scroll Wheel to adjust the Cycle setting.
When the settings for each time Time of Use level are
complete, press [Ok] to save the changes and return to
the Energy screen.
Press [Cancel] to discard the changes and return to the
Energy screen.
Ok NextCancel
Setback
0 ºF
0 ºF
0 ºF
0 ºF
Cycle
100%
100%
100%
100%
TOU
Low:
Medium:
High:
Critical:
SETBACK AND CYCLE
12 3
Ok NextCancel
Setback
0 ºF
3 ºF
6 ºF
9 ºF
Cycle
100%
100%
100%
100%
Price
SETBACK AND CYCLE
<=0.10 $
<=0.15 $
<=0.20 $
> 0.20 $
Adjusting Energy Setback and Cycle