3. Node & Radio Features
Node Features:
Basics
Battery Power
Qty. x 1 (3.6V Lithium primary D-Cell ER34615)
Accuracy Stop Voltage
2.7VDC
Mesh Stop Voltage
2.1VDC
Battery Connection
Standard Aluminium Battery Holder
Working Current (DC)
Max. 210mA
Local Storage
Min. 450 Messages during Meshing
L x W x H
Interface Node: 100 x 100 x 60mm
Weight
0.6kg
External Sensor Size and Weight
Depending on the specific sensor connected
(external cable length ≤ 1.0m)
Cable Gland
Qty. 1 x EMC-CMA12 for external sensor connection
Wire Connection
Spring type wiring terminal
Primary Sensor
Sensor Type
Signal Output Range (0 to Vcc_Out)
Power Input Voltage (Vcc_Out) @ max.
100mA
0-1.8V
1.8V±0.05V
0-2.5V
2.5V±0.05V
0-3.3V
3.3V±0.05V
0-5.0V
5.0V±0.05V
Notice: Power On Time to External Sensor: 1s power on before samples are taken.
Please confirm the sensor stable time before use.
Accuracy
0.05%F.S.
Resolution
0.18mV
Standard System Parameter
Temperature
Range: -40 to 85°C; Accuracy: ±1°C; Resolution: 0.1°C
Voltage
Accuracy: ±0.1V