Wisen Innovation Technical Doc. No.2021 WiSenMeshWAN® 4-Channel RS485 Interface Node - User Manual WiSenMeshWAN® RS-485 Interface Node User Manual 6510 Wuxi Wisen Innovation Co., Ltd. August 2021 www.wisencn.
Wisen Innovation Technical Doc. No.2021 WiSenMeshWAN® 4-Channel Laser Distance Sensor Node - User Manual Revision History and Clarification Rev. Issue Date Revisions Written By Revised By V1.0 17/11/2020 1st Issue Xiaoyan Huang Dr. Yan Wu V1.1 04/08/2021 Minor wording changes. Xinhu Nie Dr. Yan Wu Document Definition: It defines the specifications (i.e.
Wisen Innovation Technical Doc. No.2021 WiSenMeshWAN® 4-Channel Laser Distance Sensor Node - User Manual Table of Contents 1. Product Introduction................................................................................................................................................... - 4 2. System Structure Layout ............................................................................................................................................. - 5 3. Node & Radio Features ..............
Wisen Innovation Technical Doc. No.2021 WiSenMeshWAN® 4-Channel Laser Distance Sensor Node - User Manual 1. Product Introduction The WISENMESHWAN® 4-Channel RS485 Interface Node is one of the key products in our patented WISENMESHWAN® geotechnical safety monitoring system. Working together with the WISENMESHWAN® gateway product and node products, it intelligently delivers the real-time data from all different sensors outputting RS485 signal to the information centre.
Wisen Innovation Technical Doc. No.2021 WiSenMeshWAN® 4-Channel Laser Distance Sensor Node - User Manual 2. System Structure Layout Figure 2. System Structure Layout. www.wisencn.
Wisen Innovation Technical Doc. No.2021 WiSenMeshWAN® 4-Channel Laser Distance Sensor Node - User Manual 3. Node & Radio Features Node Features: Basics Battery Power Qty. x 4 (3.6V Lithium primary D-Cell ER34615) Accuracy Stop Voltage 2.7VDC Mesh Stop Voltage 2.1VDC Battery Connection Standard Aluminium Battery Holder Local Storage Min. 450 Messages during Meshing Working Current Max. 380mA (Typical: 150mA) Alternative DC Input 7-32VDC@Min. 1A Local Storage Min.
Wisen Innovation Technical Doc. No.2021 Inspection Period WiSenMeshWAN® 4-Channel Laser Distance Sensor Node - User Manual Every 3 Years by Manufacturer (or inspected by arranged methods) Industrial Standard Casing and Painting Materials Aluminium-Alloy Die Castings 12 (Epoxy Polyester Powder Coating) IP Rating >= IP66 Operating Temperature -10 to 50°C Radio Features: FCC 915MHz System CE 868MHz System Radio Band 902-928MHz 865-868MHz Central Frequency (Default) 905/910/915/920/925MHz 865.
Wisen Innovation Technical Doc. No.2021 WiSenMeshWAN® 4-Channel Laser Distance Sensor Node - User Manual 4. Terminologies Figure 3. 4-Channel RS485 Interface Node - Internal Configuration Terminologies, where: No. Terminology 1 Mesh Antenna 2 Vcc_Out Switch 3 On/Off Switch 4 External 3.6V Power Input 5 External DC Power Input www.wisencn.
Wisen Innovation Technical Doc. No.2021 WiSenMeshWAN® 4-Channel Laser Distance Sensor Node - User Manual 5. Operation Procedures 5.1.System Deployment Notifications 1) Location: The deployment location is usually determined by the desired monitoring or inspection location; 2) All the Serial Numbers of a Unit must be recorded against their site references; 3) Before it is switched on, a gateway must be deployed, powered on and proven to be working properly.
Wisen Innovation Technical Doc. No.2021 WiSenMeshWAN® 4-Channel Laser Distance Sensor Node - User Manual 5.3.Mounting Options The node fixings must be rigid for the sensor to measure accurate data. Movement in the fixings will affect the readings. 6.
Wisen Innovation Technical Doc. No.2021 WiSenMeshWAN® 4-Channel Laser Distance Sensor Node - User Manual the battery. Notices : i. Case One: If any change has been made from the list above, please inspect the data from the remote server; ii. Case Two: If all the actions from the list above have not cured the problem, please contact Wisen. We will be happy to help. 7. Package and Accessories Standard: No. Items Dimension (mm) Qty.
Wisen Innovation Technical Doc. No.2021 WiSenMeshWAN® 4-Channel Laser Distance Sensor Node - User Manual 2)Electric Safety To install the battery into a holder, please follow the “+” (positive) and “-” (negative) signs in any Wisen product. Wrong orientation of a battery could potential cause unit damage. Notice : The orientation of battery can vary among products.
FCC Warning This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.