User's Manual

Wisen Innovation Technical Doc. No.2021 WiSenMeshWAN® Mini Smart Gateway - User Manual
www.wisencn.com Page - 9 - of 11
A. Remote Inspection of historical data, to identify:
a) Whether the heart-beat message has been sent back successfully at each time interval;
b) Whether the voltage in the heart-beat message is as expected, if not, please check the USB power
supply;
c) Whether the signal strength has become significantly weaker, if yes, please check the antenna has been
screwed on firmly;
B. On-site Inspection: if all above are good, please arrange for an on-site inspection to check:
a) Whether the Mini Gateway has visible external damage;
b) Whether the antenna is bent or damaged and the node (gateway or sensor node) is not blocked by
new construction, e.g., hoardings;
c) When it is possible, check that the signal strength is normal by using a spectrum analyser;
d) Whether any connectors are loose.
Notices :
i. Case One: If any change has been made from the list above, please inspect the data from the remote server;
ii. Case Two: If all the actions from the list above have not cured the problem, please contact Wisen. We will be
happy to help.
7. Package Information
Standard:
No.
Items
Dimension (mm)
Qty.
1
WiSenMeshWAN
®
Mini Smart Gateway
52x50x40
1
2
Mesh Antenna
200
1
3
User Manual*
Downloadable from Wisen
Visualisation Platform.
4
Inspection Report*