Cut Sheet

3
Catalog No./Item Description/Specifications
RFB9 9-Gang Recessed Floor Box- 14 5/16" L x 12 1/8" W x
4 1/8" D [364mm x 322mm x 105mm] – Adjustable before
concrete pour. Horizontal mounting of power devices allows
for use of larger sized power devices in a shallow depth pour.
Provided with mudcap to prevent entry of concrete during pour.
Cover assembly and device plates sold separately.
RFB9-OG 9-Gang Recessed On-Grade Floor Box- 14 5/16" L x 12 1/8"
W x 4 1/8" D [364mm x 322mm x 105mm] – Adjustable before
concrete pour. Horizontal mounting of power devices allows
for use of larger sized power devices in a shallow depth pour.
Provided with mudcap to prevent entry of concrete during pour.
Cover assembly and device plates sold separately.
NOT E: The RFB9 has one 6-gang compartment on one side of
the box, and the other side has three
1-gang compartments. The 6-gang compartment is for
communication devices only.
RFB9 Recessed Floor Boxes Ordering Information
12 5/8"
[321mm]
14 3/4"
[356mm]
4 1/8"
[105mm]
Combination
(2) 1" & 1 1/4"
concentric
trade size KO
Combination 1" & 1 1/4"
concentric trade size KO
1-gang
43 cu. in. [705ml]
Combination 3/4" & 1"
concentric trade size KO
1-gang
43 cu. in. [705ml]
Combination (4)
1" & 1 1/4" concentric
trade size KO
Combination (3)
1" & 1 1/4" concentric
trade size KO 6-gang
132 cu. in. [2163ml]
Combination (2)
3/4" & 1" concentric
trade size KO
NOT E: The RFB9 has one 6-gang compartment on one side of
the box, and the other side has three
1-gang compartments. The 6-gang compartment is for
communication devices only.
12 5/8"
[321mm]
14 3/4"
[356mm]
4 1/8"
[105mm]
Combination
(2) 1" & 1 1/4"
concentric
trade size KO
Combination 1" & 1 1/4"
concentric trade size KO
1-gang
43 cu. in. [705ml]
Combination 3/4" & 1"
concentric trade size KO
1-gang
43 cu. in. [705ml]
Combination (4)
1" & 1 1/4" concentric
trade size KO
Combination (3)
1" & 1 1/4" concentric
trade size KO 6-gang
132 cu. in. [2163ml]
Combination (2)
3/4" & 1" concentric
trade size KO
NOT E: RFB9-OG for on-grade applications is painted with
fusion-bonded epoxy designed for use on metal
reinforcement bar and related accessories before
encapsulating in concrete.
CA UT IO N: When used in bare concrete or terrazzo covered
floors, Part number #RFB119-PAN must be used.
RFB119-PAN is sold separately. See Accessories
on page 4.
CAUTION: Minimum floor covering thickness 1/4"
[6.35mm].
CA UT IO N: When used in bare concrete or terrazzo covered
floors, Part number #RFB119-PAN must be used.
RFB119-PAN is sold separately. See Accessories
on page 4.
CAUTION: Minimum floor covering thickness 1/4"
[6.35mm].
Country of Origin: Mexico
Country of Origin: Mexico