Cut Sheet
5
Catalog No./Item Description/Specifications
RC9AMDTCGY* Poke-Thru Assembly- All
RC9AMDTCBK* All communication device
RC9AMDTCAL* accepts up to four UTP
RC9AMDTCBS* connectors. The RC9AMDTC
Series requires a 3" core hole
(3 1/16" [78mm] actual hole
diameter).
• Includes with bezels to
accept 4 Ortronics TracJack
modular jacks and 2
Ortronics Series II modular
jacks. (Sold separately.)
• Wiremold Open System
Inserts.
UL Listed for tile, carpet,
and wood covered floors.
For complete listing of
RC9AMDTC Series
accessories, see current
version of Product
Specification Sheet ED1215.
Catalog No./Item Description/Specifications
RC9A15TCGY-LJB Poke-Thru Assembly –
RC9A15TCBK-LJB Prewired 15A quad receptacle
RC9A15TCAL-LJB can be wired as standard quad
RC9A15TCBS-LJB receptacle or isolated ground.
Unit also includes two
openings for pass-through
capability for one 4-pair
Category 5e or Category 6
cable per opening.
The RC9 Series requires a 3"
core hole (3 1/16" [78mm]
actual hole diameter).
UL Listed for tile, carpet,
and wood covered floors.
For complete listing of
RC9ATC Series accessories,
see current version of Product
Specification Sheet ED1215.
Chicago Approved Poke-Thru Devices Ordering Information
(Continued)
16 5/8"
[422mm]
9"
[228mm]
Protection from water,
dirt, and debris.
Protection from water,
dirt, and debris.
NOTE:
• COM75 Adapter included.
• Maximum concrete slab depth for
RC9-LJB Series = 5.391" [136mm].
• For installations in the City of Chicago, install an EMT
compression fitting (not supplied) to the conduit system and
a junction box suitable for use in environmental air spaces, if
required, (not supplied). Complete installation per NEC and
local codes.
Maximum Allowable Copper Cross-Sectional Area:
RC9 Power Compartment only
= .01536 sq. in. [9.91mm2].
RC9 Each Communication Compartment only
=
.0040 sq. in. [2.58 mm2].
NOTE:
• Adapter included.
• Maximum concrete slab depth for
RC9AMDTC Series = 5.391" [136mm].
• For installations in the City of Chicago, install an EMT
compression fitting (not supplied) to the conduit system and
a junction box suitable for use in environmental air spaces, if
required, (not supplied). Complete installation per NEC and
local codes.
Maximum Allowable Copper Cross-Sectional Area:
RC9AMD Communication Compartment only
= .01600 sq. in. [10.324mm2].
Catalog Number Explanation
RC9A15TCAL-LJB
RC9 A 15 TC AL LJB
Identifies Identifies Identifies Identifies Color of Identifies
Poke-Thru Assembled 15A Quad that Unit is Cover Junction Box
Series Unit (A) or Power Approved for Assembly (Not included)
Cover (C) Receptacle Tile & Carpet (See below
Floors for details)
Catalog Number Explanation
RC9AMDRTTCAL
RC9 AMD TC AL
Identifies Identifies Identifies Identifies Color
Poke-Thru Assembled that Unit is of Cover
Series Unit (A) or Approved for Assembly
Cover (C) Tile and (See below
Carpet Floors for details)
NOTE: Modular Jacks
sold separately.
Poke-Thru Devices on this page are available in some or all of the
following cover color options as indicated by the part numbers:
GY – Gray painted flange with gray nonmetallic cover,
BK – Black painted flange with black nonmetallic cover,
VY – Ivory painted flange with ivory nonmetallic cover,
AL – Brushed Aluminum flange with black nonmetallic cover
BS – Brushed Brass flange with black nonmetallic cover
AA –
Brushed Aluminum flange with aluminum-colored nonmetallic cover
AB – Brushed Brass flange with brass-colored nonmetallic cover