Catalog No./Item Description/Specifications
6001A Coupling –
For joining lengths
of 6000B.
G6000WC Wire Clip –
For holding conductors
in place.
G6001DA
†
Divider Clip – For holding G6000DA
Divider in place to divide raceway
into 1/3, 1/2, or 2/3 compartments.
6000 Raceway divided into
1/3 compartments will not
accept devices.
G6001TX Converter Coupling – For converting
6011TX or 6017TX into a tee or cross.
For tee, one required; for cross,
two required.
G6008A C-Hanger – For suspending 6000 or
4000 Raceway from structural ceiling.
Designed for use with 3/8" [9.5mm]
rod. Hangers should be installed no
more than 5
'
[1.525m] apart along
raceway run. Can be bolted back-to-
back for dual runs of 4000, 6000, or
to a G3008C for combined runs with
3000 Raceway.
V4000C075/ Pre-Cut Cover 7.5" [191mm] –
G4000C075* For mounting devices on 12"
[305mm] centers with 4007, 4046,
4048, and 4049 Series plates.
V4000C135/ Pre-Cut Cover 13.5" [345mm] –
G4000C135 For mounting devices on 18"
[457mm] centers with 4007, 4046,
4048, and 4049 Series plates.
V4000C195/ Pre-Cut Cover 19.5" [495mm] –
G4000C195 For mounting devices on 24"
[610mm] centers with 4007, 4046,
4048, and 4049 Series plates.
V4000C315/ Pre-Cut Cover 31.5" [800mm] –
G4000C315 For mounting devices on 36"
[915mm] centers with 4007, 4046,
4048, and 4049 Series plates.
Catalog No./Item Description/Specifications
V6006 Connection Cover – Use where two
G6006 sections of 4000 or 6000 Cover, not
squarely cut, come together.
V6010B Blank End Fitting – For closing open
G6010B end of 6000.
V6011TX Combination Flat Elbow – For
G6011TX using as a flat elbow, tee, or cross,
(one 6001TX required for tee; two
for cross; not included).
V6012TX Internal or External 45° Elbow –
G6012TX For making internal or external 45°
turns in a run of 6000. Can also be
assembled as an inverted 45° elbow.
V6014A Connector Fitting – Has 1 1/4", 1 1/2"
G6014A and 2" [32mm, 38mm and 51mm] trade
size KOs in back and on each side.
V6017TX Combination Internal/External 90°
G6017TX Elbow – For use as internal or external
elbow, straight-through fitting, tee, or
cross (one G6001TX required for tee or
straight through fitting; two for cross;
not included).
V6046KD Circuit Breaker Housing – KOs in
G6046KD cover can be removed for installation
of three single-pole breakers. For use
with the following breakers rated
100A maximum.
6000 Raceway Fittings
1 1/2"
[38mm]
1 1/2"
[38mm]
7 7/8"
[200mm]
6 7/8"
[175mm]
* 4000C and 6000C are compatible with 4000B and 6000B Raceway.
** 6001A Rigid Coupling available on custom order to increase spacing to 10' [3.050m].
†
G6001DA Divider Clips are required to hold divider in place.
1 3/4"
[44mm]
1"
[25mm]
2 3/8"
[60mm]
3"
[76mm]
2 7/8"
[73mm]
3"
[76mm]
2 1/2"
[64mm]
3 5/16"
[84mm]
4 3/4"
[121mm]
MANUFACTURER SERIES
General Electric THQC, THHQC
Westinghouse Quicklag, C, QCH
2 3/8"
[60mm]
4 9/16"
[116mm]
2 1/2"
[64mm]
4 1/4"
[108mm]
12"
[305mm]
3 1/2"
[89mm]