2.1
Environmental DO-160G
Testing is accomplished in accordance with DO-160G, Environmental Conditions and
Test Procedures for Airborne Equipment. The following DO-160G categories and test
conditions are based on the design of the ABR and the aircraft antennas for the
intended installation inside or outside of the pressure vessel. The Radio contains no
lithium battery. The ABR is designed to operate in airframe areas that meet the
environmental conditions outlined in the DO-160G Table 2.1-1 below. It is the
responsibility of the installer to ensure the selected location meets the environmental
conditions. The ABR and antennas are not designed to be installed in wings or wheel
well areas.
See Table 2.1-1and 2.1-2 for the applicable WSS System DO-160 requirements.
Table 2.1-1 ABR Radio DO-160G Categories
DO-
160G
Section
Description
Sub Section Description
WSS Test Conditions
ABR
Radio
4
Temperature
and Altitude
4.5.1 Ground Survival Low Temp
4.5.1
Operating Low Temp
4.5.2
Ground Survival High Temp
4.5.3
Operating High Temp
4.6.1
Altitude
4.6.2
Decompression
F2
-55 ºC
-55 ºC
+85 ºC
+70 ºC
55,000 ft.
50,000 ft.
5
Temperature
Variation
B
-55 ºC/min to +70ºC
max (5 ºC/min)
6
Humidity
B
Cat B: 95% relative
humidity at 65 ºC
(55 ºC for Cat C)
7
Operational
Shocks and
Crash Safety
B
Normal Operational,
6G, 11 msec, 3 axes,
sawtooth Crash
Safety (Impulse),
20G, 11
msec, 3 axes,
sawtooth (Non-
Operational) Crash
Safety
(Sustained), 18G
(Non-Operational)
8
Vibration
Cat S;
Curve C
4.12Grms
9
Explosive
Atmosphere
E
Non-ignition
10
Waterproofness
Y
Condensing water test