User guide
title section to drag them up and down the list to rearrange.
Report Builder Settings
Settings for the report builder can be found by clicking the Settings menu on the right of the
menu bar.
Automatic Classification (Wi-Spy
Mode)
Chanalyzer will automatically identify a transmission once a signature has been created.
Devices with separate center frequencies will need separate classifiers created. Chanalyzer
uses the outline view to match classifier patterns in a spectrum recording. When a classifier
matches the shape in the outline by a large percentage, it will draw it in the density view if
the transmitter display option is enabled.
Threshold Settings
There are two sliders that act as threshold settings to adjust the rate at which Chanalyzer
identifies transmitters in the Density View. By lowering the threshold, Chanalyzer will identify
more often with lower confidence levels. Confidence levels can be adjusted individually or as
a group.
Master Confidence Slider
The master confidence threshold slider changes how frequent the classifier will be drawn in
the density view.
Individual Confidence Threshold Slider
Each classifier has its own threshold settings. The confidence level of each classifier is listed
next to the slider. Due to the different nature of transmitters, classifiers should have
different confidence levels. Each classifier can be adjusted under the master threshold slider.
Chanalyzer by MetaGeek USER GUIDE page 21