User's Manual

Draft
R03.d RT 1000 v1.3 Deployment Guide 43
© 2010-2011 Wireless Seismic, Inc. All rights reserved.
Backhaul
Configure the Radios
4.3 Configure the Radios
The FMQuadro Web Interface is used to configure the radio channels. The radio
licenses are pre-configured by Wireless Seismic, Inc. This section describes how to
connect the radios to a computer and configure them.
Check the radios before connecting them to any switch.
4.3.1 Create a Private Network
Create a private network between the computer and the Fluidmesh radio.
1 Prerequisites:
Windows computer
Browser with Adobe Flash
AC Power
PoE Injector
Two Ethernet Cables
2 Power on the computer.
3 Connect the components (see Figure 4–17 Fluidmesh Radio Private Network on
page 44):
Plug the PoE injector into an AC outlet.
Connect the computer to the PoE injector with an Ethernet cable.
Connect the Fluidmesh radio to the PoE injector with an Ethernet cable. The
radio powers up.
FM1100 – Connect to LAN 1
FM3100 – There is only one connector
NOTE
The expected configuration in the RT 1000 system is as follows:
FM1100 = mesh point (remote backhaul)
FM3100 = mesh end (central backhaul)
NOTE
All Fluidmesh units are preconfigured with an IP address of
192.168.0.10.
CAUTION
Power up only one radio at a time. Never place two powered-up radios
next to each other. It is possible to damage the radio receivers if
multiple radios are powered up in close proximity.