User's Manual

Draft
RT 1000 v1.0 18 Deployment Guide R00.f
© 2010-2011 Wireless Seismic, Inc. All rights reserved.
4
Testing and Maintaining the
Equipment
4.1 Overview
xxx
4.2 Testing the Layout
xxx
the crew is doing roll-on, roll-off acquisition. This means that only part of the
patch, ten lines, needs to be ready in order to begin production
parameter testing, can begin as soon as one line is laid out, connected, and
tested
4.2.1 Line Tests
When the correct geometry has been applied to each WRU and the geometry
accuracy has been confirmed, the Observer will begin line testing. In the
warehouse before mobilization to the field the WRUs may have passed a series
of BISTs (built in self tests), but these will need to be repeated after
deployment. This can be done from the CSS, or can be done “ahead of the
recorder” using an HRA in troubleshooter mode. Possible BISTs:
• Equivalent Input Noise (EIN)
• Total harmonic Distortion (THD)
• Pulse
• Calibration
• Channel gain and phase error
WARNING
In order to comply with FCC radio frequency (RF) exposure
requirements, the RT 1000 units must be installed so that a minimum
separation distance of 20 cm is maintained between the antenna(s) and
all persons at all times during normal operation.