User's Manual Part 2

Draft
RT System 2 v2.3.0 136 Deployment Guide R01.b
© 2010-2013 Wireless Seismic, Inc. All rights reserved.
7
7. Batteries
See “Batteries” on page 192 for the French translation of this chapter.
Voir “Batteries” sur la page 192 pour la traduction française de ce chapitre.
This chapter provides information about the batteries and battery requirements used in
the Wireless Seismic, Inc. RT System 2.
7.1 Lithium Ion Batteries
This section provides information regarding the characteristics, use, and handling of
lithium ion batteries. See the following sections for details:
“Specifications” on page 136
“Handling and Safety Guidelines” on page 137
“Transportation” on page 138
“Storage” on page 139
7.1.1 Specifications
The RT System 2 uses one or two custom intelligent lithium-ion batteries with self-
contained charging circuitry that protects the batteries from overcharge, discharge,
short circuits, or extreme temperature charging.
Battery specifications are shown in the following table:
Table 7–1 Lithium Ion Battery Specifications
Item Description Value
Voltage Nominal 3.7 VDC
Shut-off 2.8 VDC
Full (90%) charge 4.1 VDC
Overcharge Voltage 4.28 VDC
Over Discharge Voltage 2.80 VDC
Current Maximum Charge Current 2 A
Consumption Active Mode 4.2 mA maximum
Consumption Sleep Mode 66 A maximum
Full (90%) charge mAh Approximately 12,000 mAh at
nominal voltage
Full (90%) charge mWh Approximately 44,400 mWh
at nominal voltage
Capacity 48.8 Watt hours