User's Manual
5Mbps Draft
46 RT 1000 1.5.0 Deployment Guide R03.h
© 2010-2012 Wireless Seismic, Inc. All rights reserved.
3. Backhaul
Configure the Radios
3.3 Configure the Radios
The FMQuadro™ Web Interface is used to configure the radio channels. The radio
licenses are pre-configured by Wireless Seismic, Inc. This section describes how to
connect the radios to a computer and configure them.
Check the radios before connecting them to any switch.
3.3.1 Create a Private Network
Create a private network between the computer and the Fluidmesh radio.
1 Prerequisites:
● Windows computer
● Browser with Adobe Flash
● AC Power
● PoE Injector
● Two Ethernet Cables
2 Power on the computer.
3 Connect the components (see Figure 3–16 Fluidmesh Radio Private Network on
page 47):
● Plug the PoE injector into an AC outlet.
● Connect the computer to the PoE injector with an Ethernet cable.
● Connect the Fluidmesh radio to the PoE injector with an Ethernet cable. The
radio powers up.
► FM1100 – Connect to LAN 1
► FM3100 – There is only one connector
NOTE
The expected configuration in the RT 1000 system is as follows:
FM1100 = mesh point (remote backhaul)
FM3100 = mesh end (central backhaul)
NOTE
All Fluidmesh units are preconfigured with an IP address of
192.168.0.10.
CAUTION
Power up only one radio at a time. Never place two powered-up radios
next to each other. It is possible to damage the radio receivers if
multiple radios are powered up in close proximity.