User's Manual
PAC Configuration Manual
Wireless Matrix Corporation #102, 1530 - 27 Avenue NE Page 60 of 62
Document # xxx-xxx-xxx Calgary, AB, Canada T2E 7S6
2002.02.01 Ph. 403.250.3949 Fax 403.250.8163 www.wrx-ca.com
6.2.3 RPM meter
GDN ADD INT ? 9xx 1 3 5 255 6 float
PID ?
Point index 9xx
Address (channel number) 1
F1 3 (Identifies RPM meter)
F2 5 (Sampling interval: 0 instantaneous
value, 1 and greater indicates the sample
rate. For example, 5 indicates a calculation
every 5 seconds.)
F3
255 (Enable 2 kΩ pull-up resistor)
F4
6 (De-bounce interval of 24 µs (6 x 4µs))
Point type Float
6.2.4 Frequency Meter (kHz)
GDN ADD INT ? 9xx 1 4 5 255 6 float
PID ?
Point index 9xx
Address (channel number) 1
F1 4 (Identifies frequency (in kHz) meter)
F2 5 (Sampling interval: 0 instantaneous
value, 1 and greater indicates the sample
rate. For example, 5 indicates a calculation
every 5 seconds.)
F3
255 (Enable 2 kΩ pull-up resistor)
F4
6 (De-bounce interval of 24 µs (6 x 4µs))
Point type float