o software compatibility. For example, whether desired features can be enabled with the
redeployed module in the network.
o hardware compatibility; for example, where a CMMmicro is deployed.
o the value of each configurable parameter. Whether all are compatible in the new destination.
remembering to use auto discovery to add the redeployed SM to the network in Wireless Manager
Wiring to Extend Network Sync
The following procedure can be used to extend network sync by one additional hop. Where a
collocated module receives sync over the air, the collocated modules can be wired to pass the sync as
follows:
Procedure 1 Wiring to extend network synchronization
1
Connect the GPS Utility ports of the collocated modules using a sync cable with RJ-11
connectors.
2
Set the Sync Input parameter on the Configuration page of the collocated AP timing master
to Sync to Received Signal (Timing Port).
3
Set the Frame Timing Pulse Gated parameter on the Configuration page of the collocated
SM timing slave to Enable.