User's Manual

Table Of Contents
Using the Throughput Monitoring Tool (AP)
Using Tools in the GUI
5-24
pmp-0049 (September 2012)
Figure 49 Throughput tab of the AP
The following configuration parameters are available on the Throughput tab GUI pane, and a radio
reboot is not required when configuring these parameters:
Table 36 Congested AP Indicator attributes
Attribute
Meaning
Throughput Monitoring
This enables or disables the monitoring of sector throughput
and packet discards. This parameter is disabled by default.
SNMP Trap on RF
Overload
This enables or disables the sending of an SNMP trap when an
AP overload condition is reached (based on Downlink RF
Overload Threshold).
Downlink RF Overload
Threshold
This parameter determines the overload threshold in percent of
packets discarded that triggers the generation of an SNMP
trap.
Downlink RF Link Status
This field displays the status of the capacity of the RF link.
Time Period Length
Time Period Ending
These two configuration parameters determine what set of
collection samples to show on the GUI display. The Time
Period Length can be set from one to three hours. Time Period
Ending allows the operator to set the end time for the set of
collection samples to display.
Below the configuration settings are three tables that display the statistics that are collected.
Board Performance Statistics Table
This table contains a row that corresponds to each 1 minute statistics collection interval. Each row
contains the following data aggregated for the entire AP:
Ethernet Throughput - Statistics collected at the Ethernet port:
o kbps in average throughput over the collection interval in Kbps into the AP on the Ethernet
Interface