User's Manual

Table Of Contents
PMP 450 Operations Guide
Using the OFDM Frame Calculator Tool for
Collocation (AP or SM)
pmp-0049 (September 2012)
5-17
Attribute
Meaning
Downlink Data
Initially set this parameter to the same value that the AP has for its
Downlink Data parameter (percentage). Then, as you use the Frame
Calculator tool in Procedure 6, you will vary the value in this
parameter to find the proper value to write into the Downlink Data
parameter of all APs in the cluster.
PMP 450 Series APs offer a range of 15% to 85%, and default to 75%.
The value that you set in this parameter has the following interaction
with the value of the Max Range parameter (above):
The default Max Range value is 5 miles and, at that distance, the
maximum Downlink Data value (85% in PMP450) is functional.
Control Slots
Set this parameter to the value of the Control Slot parameter is set in
the APs.