Interpreting messages in the Event Log
pmp-0049 (September 2012)
4-17
Event Message
Meaning
FatalError()
The event recorded on the line immediately beneath this message
triggered the Fatal Error().
Loss of GPS Sync Pulse
Module has lost GPS sync signal.
Machine Check Exception
This is a symptom of a possible hardware failure. If this is a recurring
message, begin the RMA process for the module.
RcvFrmNum = 0x00066d
ExpFrmNum = 0x000799
Something is interfering with the control messaging of the module. Also
ensure that you are using shielded cables to minimize interference.
Consider trying different frequency options to eliminate or reduce
interference.
System Reset Exception --
External Hard Reset
The unit lost power or was power cycled.
System Reset Exception --
External Hard Reset
WatchDog
The event recorded on the preceding line triggered this WatchDog
message.