Product Manual

Stinger User Manual Page 11 of
33
Point subscriber module in direction of the access point. Remember that when utilizing
the
internal patch antenna the energy is radiated out in a 60° horizontal by 60° vertical
pattern.
Set the web page to auto-refresh (see Configuration section for further
information)
Go to Alignment web page. Ensure that “RSSI Only Mode” is
disabled.
Click “Enable Aiming Mode
button.
The module has a series of states that it will go through to register to an access
point.
Those states are: scanning, syncing, registering, and registered. RSSI and Jitter will
not
report on the web page till the unit is registered. If the module will not register ensure
that
there is line-of-sight, the access point module is transmitting, the color codes match,
and
that the subscriber is within the appropriate distance to the access point as specified
by
Stinger.
Slowly adjust the positioning of the subscriber module and monitor the Alignment
web
page for a reading of the RSSI and Jitter. Lock down the module when
appropriate.
Click “Disable Aiming Mode
button.
Perform a link test to check the efficiency of the link. See Link Test section for
further
information. The efficiencies must be above 90% in both the up and down link for
major
packet loss to not
occur.