Product Manual
Stinger User Manual Page 11 of
33
•
Point subscriber module in direction of the access point. Remember that when utilizing
the
internal patch antenna the energy is radiated out in a 60° horizontal by 60° vertical
pattern.
•
Set the web page to auto-refresh (see Configuration section for further
information)
•
Go to Alignment web page. Ensure that “RSSI Only Mode” is
disabled.
•
Click “Enable Aiming Mode”
button.
•
The module has a series of states that it will go through to register to an access
point.
Those states are: scanning, syncing, registering, and registered. RSSI and Jitter will
not
report on the web page till the unit is registered. If the module will not register ensure
that
there is line-of-sight, the access point module is transmitting, the color codes match,
and
that the subscriber is within the appropriate distance to the access point as specified
by
Stinger.
•
Slowly adjust the positioning of the subscriber module and monitor the Alignment
web
page for a reading of the RSSI and Jitter. Lock down the module when
appropriate.
•
Click “Disable Aiming Mode”
button.
•
Perform a link test to check the efficiency of the link. See Link Test section for
further
information. The efficiencies must be above 90% in both the up and down link for
major
packet loss to not
occur.