20. Programmable functions by over-ride switch
The L-TR53B model’s functions 【valet, daily auto-start time ,temperature-controlled auto start 】can be programmed for
ON/OFF modes by means of over-ride switch in the following procedure.
(a)、Turn the ignition OFF
(b)、Press and release the over-ride switch for assigned number of times to acquire desired mode settings [ 3 times for valet
change mode setting ],[ 4 times for daily auto-start time setting],[5 times for temperature-controlled auto-start setting]. The
number of siren’s chirps follow the equal number press on the over-ride switch to confirm the current mode setting .
(c)、Turn the ignition ON when the desired mode setting is reached. ( But engine must not be running)
(d)、To choose the ON and OFF in each mode, setting, press again the over-ride switch 1 or 2 times. The factory default setting
is marked with shaded description like
OFF.
Manual features program table
No of presses on over-ride switch VS active mode
setting
Single press Double presses
3 times to enter valet mode setting ON OFF
4 times to enter daily auto-start time mode setting
ON{see note below } OFF
5 times to get temp-controlled auto start time mode
setting
ON OFF
Siren and L E D indicator 1 2
Note: If the daily auto-start time ON is programmed, the engine will be running immediately when the ignition key is turned
OFF .( Use the remote LCD unit to shut off the engine in this case.)
19. Page-out call from car
If page-out call button on vehicle-base antenna case is pressed。
l The remote unit displays 『 』on the screen and sounds melody
21. Manual Arm and Disarm
( In case the remote transmitter is lost)
Manual Arm Mode
(a) Turn the ignition key to ON position (But engine must not be running)
(b) Press and release the over-ride switch 8 times
(d) Turn the ignition key to OFF position (siren chirps 1 time with 1 parking light flash ).After 20 sec, the main system will
enter Arm mode .