User's Manual
5. Remote control run time with status check
(a)、Following the success of engine start; press both【 + 】simultaneously each time to allow 5 min
engine run time with maximum up to of 20 min. The remote LCD shows up t he runtime achieved. For
example the LCD’ s icon that shows『r 15』means engine run time is 15 min。
(b)、 Following the success of engine start; press and hold both 【 + 】simultaneously to check the
remaining engine run time. For example the LCD’ s icon that shows 『r 08』 means the remaining run time
is 8 min .
Note: While the engine is not running,press shortly (or for longer time) both【 + 】simultaneously to
check the current status of vehicle which will be displayed on the remote LCD .
6. Remote engine shut off
(a)、While the remote engine is running
(b)、Press and releaser【 】: the engine shuts off with 2 siren chirps and 2 parking light flashes.
l The remote LCD’ s icon 『 』will disappear but shows up the car’ s status and sounds melody.
7. Remote temperature start ON/OFF
(a)、Temperature-controlled auto-start “ON” : Press and hold both
【
+ 】 to activate this function. Siren
chirps 3 times with 3 parking light flashes. Following this function’ s activation , siren chirps 3 times with 3
flashes of par king light. The engine will start at the pre-selected temperature and begin running and
automatically shut off when the pre-set run time expires 。
(b)、Temperature-controlled auto-start “OFF” : Press and release both 【 + 】to turn the
temperature-controlled auto-start “OFF。
l The remote LCD responses as below:-
(c)、If temperature-controlled auto-start ON is activated; the remote LCD shows 『 』to confirm this function
is activated and the pre-set temperature icon like 『- 』 appear on the display. The transmitter unit
sounds melody.【When the main system sensed - temperature, the engine start automatically】。
(d)、If temperature-controlled auto-start OFF is activated; the icon『 』disappears from remote LCD and the
remote unit sounds melody。
(e)、When such feature is programmed , the temp -controlled auto-engine run will go on for maximum 2 hours
each time with a total 6 repeated cycles。
Note: The temperature can be programmed at -5º 、-10º 、-20º 、-30º depending on your requirement for
auto-engine run [RF features programmable]。
7