User Manual
Table Of Contents
COATING THICKNESS GAUGE
INSTRUCTION MANUAL
MODEL: WT2110
A.Introduction
3
1 2 4
Horizontal color-screen
high-definition display
Coating Thickness G au ge
ESC
OK
MENU
③
①
② ⑤
④
⑦
⑨
⑧
⑥
7
5
6
8
a
c
e
g
b
d
f
h
a
b
a
b
c
d
e
f
Vertital color-screen
high-definition display
with high-definition display, which can quickly, non-destructively
and accurately measure non-magnetic coating thickness on
magnetic metal substrates and non-metallic coating thickness
measurement on non-magnetic metal substrates. At the same
time it can automatically identify magnetic metal substrate and
non-magnetic metal substrate, and is widely used in
manufacturing, metal processing industry, chemical industry,
commodity inspection and other testing areas.
This product is a color-screen portable coating thickness gauge
B.Functions
Menu operation and colo-screen HD display.
Thickness measurement of non-magnetic coating on magnetic
metal substrate surface and non-metallic coating on non-
magnetic metal substrate .
Two measurement methods: single measurement, continuous
measurement.
Three calibration modes: basic, offset, zero calibration.
Metric/imperial unit and storage function.
Screen rotation, charge protection, multi-interface displays,
screen brightness selection.
Automatic shutdown.
C.Name of Parts
① Up button: switch measurement modes/ increase calibration data
② Down button: switch measurement units and reduce calibration data
③ Menu and On/Off
④ Return
⑤ Confirm
⑥ LCD display
⑦ USB charging
interface
⑧ Battery door
⑨ Test probe
D.Description of charging function
1.Battery life indicator “ ” 2.Normal charging
3.Charging complete“ ” 4.Charging without battery “ ”
5.During charging, the product has temperature protection, with
protection range 3 °C ~ 45 °C or so. If the temperature is out of
protection range, will show up and charging will be stopped.
6.If charging temperature exceeds the protection range during
shutdown, the meter screen will light up for 1 second every 10
seconds.
“ ”
Warning: The charging function is only for rechargeable batteries.
Disposable batteries is prohibited from charging!
E.Measurement Interface Instruction
1 Measurement Instruction: After turning on the instrument, lightly
press the test probe on the tested substrate under
measurement interface. The measured value is the
thickness of coating on the
substrate.
2.Measured Values:
a.The title bar shows the
title and battery state of
the interface.
b.Yellow number is the
measured thickness.
c.Num is the times of
measurement.
d.SNG is the selected measurement mode (SNG is single
measurement and CTN is continuous measurement).
e.Fe on the upper right is the measured substrate (Fe is for
magnetic metal substrate;
nFe is a non-magnetic metal
substrate).
f.The green icon on the lower
right is measurement unit.
3.Measured values and trend
chart:
a.The trend chart below is the
trend of the last 20 groups
of data.
b.The trend chart shows the
high and low limit values.
4.Measured Values and Statistics:
a.Dif :Difference value compared
to the last measurement
b.Avg:Average value
c. Max:Maximum value
d. Min:Minimum value
e. High:High limit
f. Low:Low limit
g. Sdev:standard deviation
.
h. CV%:coefficient of variation
Note: The standard deviation and coefficient of variation are
calculated for the last 100 measured data.
5. Measured values vs. past
values view:
a.This interface shows the last
12 measured data.
6. Measured Values and Bar
Graph:
a.The bar graph shows the
proportion of the measured
value in the measurement
range.
b.The bar chart shows the high and low limits.
c.The measured data forms up green bar graph in the range of
high and low limit values.
d.The measured data froms up red bar graph when exceeding
high and low limits.
F.Calibration Operation
1 Basic calibration:
calibration menu and select basic calibration.
b. According to the instrument instruction, place the
corresponding calibration plate for calibration.
c. After calibration is completed, “calibration complete” will show
up at the bottom of the screen and the instrument will return to
the previous interface.
d. After the calibration is complete, you can go back to
measurement interface and perform measurement.
2. Offset Calibration:
a. Enter calibration menu and select Offset Calibration.
b. Measure the thickness of single point by following the
instrustion at the bottom of the screen.
c. Pick up the instrument and press Up/Down button to adjust the
value.
d. Press OK when the adjustment is completed. “Calibration
complete” will show up at the bottom of the screen and the
instrument will return to the previous interface.
e. After the calibration is complete, you can go back to
measurement interface and perform measurements.
3. Zero Calibration:
a. Enter calibration menu and select zero calibration.
.
a. Prepare the calibration plate and calibration base, enter
WT2110
WT2110
b. Press the instrument lightly on
the substrate as instruction at
the bottom of the screen.
c. The instrument will
automatically calibrate to zero
point.
d. “Calibration complete” will
show up at the bottom of the
screen and the instrument will
return to the previous interface.
e. After calibration is complete, you can go back to measurement
interface and perform measurements.
Note: If the measured value turns to silver gray after zero
calibration, the measured value is negative. If 0.241mm is
calibrated to zero, the measured value will be displayed as silver
gray when the original zero point is measured again.
G.Calibration Operations
1 Enter limit value interface to select limit value adjustment.
2. Adjust high limit value according to the screen instruction.
3. Short press Up/Down button to or long press Up/Down button
to adjust high limit value.
4. After adjusting high limit value, press OK button and then start
adjusting low limit value.
5. Short press Up/Down button to adjust low limit value or long
press Up/Down button to adjust low limit value.
6. After adjustment is complete, press OK button to go back to
previous interface.
.
H.Storage Management
1 Review
a. Press OK button under measurement interface to enter into
review menu.
b. Choose Check function under Review menu to view the last
measured 100 data.
c. Choose Save function under Review menu to save the
measured data (the last 100 data).
d. Select Clear function under Review menu to clear the
measured data.
. :
2 Data browsing:
a. The title bar of browsing interface displays selected unit,
average value, and the number of saved data.
b. The maximum and minimum values of saved data are marked
in red.
.
c. In the lower part of histogram
displays icon of data, and the set
high and low alarm values are in
the middle.
d. The data column above or below
alarm value is red.
e. The black line and data at the top
are the interval of histogram.
3 Storage space:
a. The storage space is divided into
100 storage areas. Each storage
area can store up to 15 data.
b. Storage with less than 15 data will occupy one storage area, and
data storage with more than 15 data and less than 100 data will
occupy multiple storage areas.
.
I.Measurement View
1 Press Up/Down button under measurement interface to switch
measurement view.
2. If a measurement view is set to be closed, this view is skipped
when you press Up/Down button under measurement interface.
3. If measurement view options are all off, the instrument
automatically opens measurement view options.
.
J.Settings
1 Screen rotation under measurement: after startup, the screen will
only rotate under the measurement interface.
2. Restore factory settings: restore default settings and clear
calibration data.
.
K.Technical Parameters
Measurement range
Resolution
Measurement error
Minimum diameter of
magnetic metal substrate
Battery
Size
Weight
0~1500um/0~59mil/0~1.5mm
( 0.1μm(<100μm),1μm(≥100μm))/
0.1mil/0.001mm
≤
>150μm ±(3%H+1μm)
150μm ±5μm
Minimum thickness of
magnetic metal substrate
Minimum radius of curvature
for magnetic convex substrate
Minimum radius of curvature
for magnetic concave substrate
12mm
0.5mm
2mm
11mm
3x1.2V NiMH battery (weight 36.5g) or 5V1A power adapter
70.30*38.6*149.59mm
136.9 including battery( )
L.Menu Chart
M.Attention
1 Keep the probe away from the measured substrate when starting
up.
2. After startup, ERR1 or ERR2 indicates probe error.
3. After startup, ERR1 or ERR2 indicates substrate error.
4. During measurement, "----" indicates that the substrate is not
calibrated.
5. During measurement, "-OL-" indicates data overflow.
.
1.Language settings >>
2.Screen rotation (on/off)
3.No operation auto off time >>
4.Key sound (on/off)
5.High backlight (on/off)
6.Selected colors >>
7.Software version >>
8.Restore factory settings >>
Setting
1.Chinese
2.English
Language
1.Two minutes
2.Five minutes
3.Ten minutes
4.Halfhour
5.Never
No operation
auto off time
1.Measure mode >>
2.Measure unit >>
Measure
1.Single(SNG)
2.Continuous (CTN)
Measure mode
1.mm
2.mil
3.um
Measure unit
1.Blue
2.Orange
3.Red
4.Purple
5.Green
6.Gray
Selected Colors
View
1.Measured Value
2.Measured Value & Trend Graph
3.Measured Value & Statistics
4.Measured Value & Last Value
5.Measured Value & Bar Graph
(on/off)
(on/off)
(on/off)
(on/off)
(on/off)
1.Measure >>
2.Calibration >>
3.Limit >>
4.Memory >>
5.View >>
6.Settings >>
Menu
1.Base calibration >>
2.Offset calibration >>
3.Zero calibration >>
Calibration
1.Adjustment of the limit value >>
2.Limit sound (on/off)
Limit
1.Look back >>
2.Browse from the first group >>
3.Browse from the selected group >>
4.Delete selected group >>
5.Delete all >>
Memory
1.Look Data >>
2.Save Data >>
3.Clear Data >>
Look back
Minimum diameter of non-
magnetic metal substrate
50mm
Minimum thickness of non-
magnetic metal substrate
0. 5mm
TIPS: Thisdeviceisequippedwithrechargeablebattery.Ifyou
receivetheproductandcannotstartup,pleaseconnect
withtheadapterforchargingbeforeuse.
Specific Declarations:
Our company shall hold no any responisibility resulting from using
output from this product as an direct or indirect evidence.