Service manual

Xfer Station 4 is a data holding location for data passed to an exit device
such as an Inserter
ACTION TO TAKE
Had the Xfer Station 2 pack previously entered Collector/Xfer Station 2
normally, no error?
Had the Xfer Station 2 pack previously exited Collector/Xfer Station 2
normally, no error?
ANY OTHER ADJUSTMENTS
This pack was marked bad.
Was there an Xfer Conveyor error in the previous cycle?
Remove and inspect this pack and other suspect packs or allow the pack
to be diverted for inspection downstream.
Set Engin. Value#55 to 1 to set all packs in the Xfer Conveyor bad.
The following device, maybe an Inserter, may have provision to divert
bad packs for inspection.
15050 “No Data From Sta 1 - Set Sta 2 Pack Bad”
HARDWARE: New Xfer Conveyor, Bridge and Two Stage
WHAT HAPPENED
Cycling, a pack reached Xfer Station 2, but the pack from Xfer Station 1
has no data.
ACTION TO TAKE
Had the Xfer Station 1 pack previously entered Xfer Station 1 normally,
no error?
Had the Xfer Station 1 pack moved to Xfer Station 2 normally, no error?
Test the sensors at Station 1 and 2.
ANY OTHER ADJUSTMENTS
This pack was marked bad.
Was there an Xfer Conveyor error in the previous cycle?
Remove and inspect this pack and other suspect packs or allow the pack
to be diverted for inspection downstream.
Set Engin. Value#55 to 1 to set all packs in the Xfer Conveyor bad.
The following device, maybe an Inserter, may have provision to divert
bad packs for inspection.
15051 “Data Overwrite Sta 2 - Set Sta 2 Pack Bad”
HARDWARE: New Xfer Conveyor, Bridge and Two Stage
WHAT HAPPENED
Cycling, a pack reached Xfer Station 2, but the data from the previous
pack associated with Xfer Station 2 is still present.
ACTION TO TAKE
Did the previous pack move to Xfer Station 3 normally, no error?
Or did the previous pack exit the Xfer Conveyor Station 2 normally, no
error?
Test the sensors at Station 1 and 2.
ANY OTHER ADJUSTMENTS
This pack was marked bad.
Was there an Xfer Conveyor error in the previous cycle?
Remove and inspect this pack and other suspect packs or allow the pack
to be diverted for inspection downstream.
Set Engin. Value#55 to 1 to set all packs in the Xfer Conveyor bad.
The following device, maybe an Inserter, may have provision to divert
bad packs for inspection.
15052 “No Data From Sta 2 - Set Sta 3 Pack Bad”
HARDWARE: New Xfer Conveyor, Bridge and Two Stage
PROBLEM ANALYSIS
420T V6LT OPERATOR & SERVICE MANUAL ISSUE 2009/06 Rev. 6/21/2011 SECTION C – PAGE 99
071-33370-400