Service manual

ACTION TO TAKE
Test the sensor at Station 2.
Test the clutch and brake at Station 2.
ANY OTHER ADJUSTMENTS
Did this pack stop under the Station Sensor? Adjust sensor, turn Xfer
Conveyor speed down, check Xfer Conveyor brakes.
This pack was marked bad.
Was there an Xfer Conveyor error in the previous cycle?
Remove and inspect this pack and other suspect packs or allow the pack
to be diverted for inspection downstream.
Set Engin. Value#55 to 1 to set all packs in the Xfer Conveyor bad.
The following device, maybe an Inserter, may have provision to divert
bad packs for inspection.
15044 “False Feed Into Xfer Station 3”
HARDWARE: New Xfer Conveyor, Bridge and Two Stage
WHAT HAPPENED
Cycling, an unexpected pack was sensed at Xfer Station 3.
ACTION TO TAKE
Did the pack at the previous Station 2 stop there?
Test the sensor at Station 3.
Test the sensor at the previous station Station 2.
Test the clutch and brake at Station 2
ANY OTHER ADJUSTMENTS
This pack was marked bad.
Was there an Xfer Conveyor error in the previous cycle?
Remove and inspect this pack and other suspect packs or allow the pack
to be diverted for inspection downstream.
Set Engin. Value#55 to 1 to set all packs in the Xfer Conveyor bad.
The following device, maybe an Inserter, may have provision to divert
bad packs for inspection.
15045 “False Feed Out Of Xfer Station 3”
HARDWARE: New Xfer Conveyor, Bridge and Two Stage
WHAT HAPPENED
Cycling, the pack at Xfer Station 3 was sensed unexpectedly leaving.
ACTION TO TAKE
Test the sensor at Station 3.
Test the clutch and brake at Station 3.
ANY OTHER ADJUSTMENTS
This pack was marked bad.
Was there an Xfer Conveyor error in the previous cycle?
Remove and inspect this pack and other suspect packs or allow the pack
to be diverted for inspection downstream.
Set Engin. Value#55 to 1 to set all packs in the Xfer Conveyor bad.
The following device, maybe an Inserter, may have provision to divert
bad packs for inspection.
15046 “No Data From Sta 2 - Set Sta 4 Pack Bad”
HARDWARE: New Xfer Conveyor, Type 5, Bridge and Collector
WHAT HAPPENED
Cycling, a pack reached Xfer Station 4, but the pack from Collector/Xfer
Station 2 has no data.
420T V6LT OPERATOR & SERVICE MANUAL ISSUE 2009/06 Rev. 6/21/2011 SECTION C – PAGE 98
071-33370-400
PROBLEM ANALYSIS