Service manual
Set Engin. Value#55 to 1 to set all packs in the Xfer Conveyor bad.
The following device, maybe an Inserter, may have provision to divert bad
packs for inspection.
15025 "Jam out of Xfer Station 3”
HARDWARE: New Xfer Conveyor, Bridge and Two Stage
WHAT HAPPENED
Cycling, a pack did not leave Xfer Station 3 within a time.
ACTION TO TAKE
Check for a jam in the Station 3.
Test the sensor at Station 3.
Test the clutch and brake at the Station 3.
ANY OTHER ADJUSTMENTS
Adjust Engin Value#9 XcvyN OutOf Sta time.
This pack was marked bad.
Was there an Xfer Conveyor error in the previous cycle?
Remove and inspect this pack and other suspect packs or allow the pack
to be diverted for inspection downstream.
Set Engin. Value#55 to 1 to set all packs in the Xfer Conveyor bad.
The following device, maybe an Inserter, may have provision to divert
bad packs for inspection.
15026 “Unknown Pack Sta 1 – Set Pack Bad”
HARDWARE: New Xfer Conveyor, Bridge and Two Stage
WHAT HAPPENED
At Power On, Motors On, an unexpected pack was sensed in Xfer Station
1.
ACTION TO TAKE
Test the sensor at Station 1.
Test the clutch and brake at Station 1.
ANY OTHER ADJUSTMENTS
This pack was marked bad.
Was there an Xfer Conveyor error in the previous cycle?
Remove and inspect this pack and other suspect packs or allow the pack
to be diverted for inspection downstream.
Set Engin. Value#55 to 1 to set all packs in the Xfer Conveyor bad.
The following device, maybe an Inserter, may have provision to divert
bad packs for inspection.
15027 “Unknown Pack Sta 2 – Set Pack Bad”
HARDWARE: New Xfer Conveyor, Bridge and Two Stage
WHAT HAPPENED
At Power On, Motors On, an unexpected pack was sensed in Xfer Station
2.
ACTION TO TAKE
Test the sensor at Station 2.
Test the clutch and brake at Station 2.
ANY OTHER ADJUSTMENTS
This pack was marked bad.
Was there an Xfer Conveyor error in the previous cycle?
Remove and inspect this pack and other suspect packs or allow the pack
to be diverted for inspection downstream.
Set Engin. Value#55 to 1 to set all packs in the Xfer Conveyor bad.
PROBLEM ANALYSIS
420T V6LT OPERATOR & SERVICE MANUAL ISSUE 2009/06 Rev. 6/21/2011 SECTION C – PAGE 93
071-33370-400